The results suggest that the use of a bullet-shaped cage, higher PDH, the presence of scoliotic curvature, and undersized fusion cages are possible risk factors for cage migration. One patient with postoperative cage migration following bilateral screw fixation underwent revision surgery, and the pedicle screw fixation was found to be disrupted. Other than in this patient, cage migration occurred only in those treated by unilateral fixation. The potential for postoperative cage migration and limitations of unilateral fixation should be considered by spine surgeons.
The findings presented in this article will contribute to the understanding of the normal appearance of the popliteomeniscal fasciculi on MRI, and of the degree of variation of this structure among the population.
The findings of this study suggest that ultrasound examination may be suitable for screening for meniscal tears. The fact that almost 10% of the lateral menisci could not be evaluated because of poor images appears to be a weakness of ultrasound.
Purpose
To evaluate and compare the femoral tunnel aperture position, graft bending angle and the magnetic resonance imaging (MRI) graft signal intensity after anatomical double‐bundle anterior cruciate ligament (ACL) reconstruction between transtibial and transportal drilling techniques of the femoral tunnel.
Methods
Eighty‐seven patients who underwent anatomic double‐bundle ACL reconstruction with hamstring tendon autograft between January 2012 and December 2014 were included in this retrospective study. Forty‐one patients underwent reconstruction using a transportal technique (TP group) and 46 patients underwent reconstruction using a transtibial technique (TT group). The anteromedial (AM) femoral aperture position and the graft bending angle were assessed using transparent three‐dimensional CT 2 weeks postoperatively. MRI assessment was performed with proton density‐weighted images in an oblique coronal plane 6 and 12 months postoperatively. Signal/noise quotient was calculated for two specific graft sites (femoral tunnel site and mid‐substance site). Femoral aperture position, the graft bending angle and signal/noise quotient were compared between the TP and TT groups.
Results
There was no significant difference in the aperture position between the two groups. The graft bending angle of the AM tunnel in the axial plane was significantly greater in the TP group (p < 0.001). On the other hand, the TP group had a significantly more acute angle in the coronal plane (p < 0.001). There was no significant difference at either site in the signal/noise quotient of the graft between the two groups at 6 months. However, the TT group had a lower signal/noise quotient at 12 months at both sites (femoral aperture: p = 0.04, mid‐substance: p = 0.004).
Conclusion
There was a significant difference in signal/noise quotient between the two drilling techniques 12 months postoperatively. There was no significant difference in femoral tunnel aperture position between the two groups. However, graft bending angle at the femoral tunnel aperture was significantly different between the two groups, indicating the possibility that graft bending angle is a factor that influences graft maturation. This indicates that the TT technique has an advantage over the TP technique in terms of graft maturation.
Pseudoaneurysm is one of the most serious complications of femoral trochanteric fracture surgery. Since the rupture of pseudoaneurysm may lead to death, early detection is important. We report the case of an 80-year-old male who developed pain in the proximal thigh and severe swelling after internal fixation of a femoral trochanteric fracture with a hip nail. Angiography revealed a pseudoaneurysm of a branch of the deep femoral artery near the interlocking screw. The vascular lesion was immediately treated by transcatheter embolization, and the vascular leakage was completely resolved with catheter embolization. After embolization, the patient's clinical state improved rapidly, and the laboratory values improved to normal after several weeks. The current case study reminds us that pseudoaneurysm can occur after intramedullary nail placement to treat a femoral trochanteric fracture.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.