We report a method for combining the detection of single molecules (digital) and an ensemble of molecules (analog) that is capable of detecting enzyme label from 10 −19 M to 10 −13 M, for use in high sensitivity enzyme-linked immunosorbent assays (ELISA). The approach works by capturing proteins on microscopic beads, labeling the proteins with enzymes using a conventional multi-step immunosandwich approach, isolating the beads in an array of 50-femtoliter wells (Single Molecule Array, SiMoA), and detecting bead-associated enzymatic activity using fluorescence imaging. At low concentrations of proteins, when the ratio of enzyme labels to beads is less than ∼1.2, beads carry either zero or low numbers of enzymes, and protein concentration is quantified by counting the presence of "on" or "off" beads (digital regime) 1 . At higher protein concentrations, each bead typically carries multiple enzyme labels, and the average number of enzyme labels present on each bead is quantified from a measure of the average fluorescence intensity (analog regime). Both the digital and analog concentration ranges are quantified by a common unit, namely, average number of enzyme labels per bead (AEB). By combining digital and analog detection of singulated beads, a linear dynamic range of over 6 orders of magnitude to enzyme label was achieved. Using this approach, an immunoassay for prostate specific antigen (PSA) was developed. The combined digital and analog PSA assay provided linear response over approximately four logs of concentration ([PSA] from 8 fg/mL -100 pg/mL or 250 aM -3.3 pM). This approach extends the dynamic range of ELISA from picomolar levels down to subfemtomolar levels in a single measurement.
Amyloid β (Aβ) peptides are proteolytic products from amyloid precursor protein (APP) and are thought to play a role in Alzheimer disease (AD) pathogenesis. While much is known about molecular mechanisms underlying cerebral Aβ accumulation in familial AD, less is known about the cause(s) of brain amyloidosis in sporadic disease. Animal and postmortem studies suggest that Aβ secretion can be up-regulated in response to hypoxia. We employed a new technology (Single Molecule Arrays, SiMoA) capable of ultrasensitive protein measurements and developed a novel assay to look for changes in serum Aβ42 concentration in 25 resuscitated patients with severe hypoxia due to cardiac arrest. After a lag period of 10 or more hours, very clear serum Aβ42 elevations were observed in all patients. Elevations ranged from approximately 80% to over 70-fold, with most elevations in the range of 3–10-fold (average approximately 7-fold). The magnitude of the increase correlated with clinical outcome. These data provide the first direct evidence in living humans that ischemia acutely increases Aβ levels in blood. The results point to the possibility that hypoxia may play a role in the amyloidogenic process of AD.
We report a method for isolating individual paramagnetic beads in arrays of femtolitre-sized wells and detecting single enzyme-labeled proteins on these beads using sequential fluid flows in microfabricated polymer array assemblies. Arrays of femtolitre-sized wells were fabricated in cyclic olefin polymer (COP) using injection moulding based on DVD manufacturing. These arrays were bonded to a complementary fluidic structure that was also moulded in COP to create an enclosed device to allow delivery of liquids to the arrays. Enzyme-associated, paramagnetic beads suspended in aqueous solutions of enzyme substrate were delivered fluidically to the array such that one bead per well was loaded by gravity. A fluorocarbon oil was then flowed into the device to remove excess beads from the surface of the array, and to seal and isolate the femtolitre-sized wells containing beads and enzyme substrate. The device was then imaged using standard fluorescence imaging to determine which wells contained single enzyme molecules. The analytical performance of this device as the detector for digital ELISA compared favourably to the standard method, i.e., glass arrays mechanically sealed against a silicone gasket; prostate specific antigen (PSA) could be detected from 0.011 pg mL(-1) up to 100 pg mL(-1). The use of an enclosed fluidic device to isolate beads in single-molecule arrays offers a multitude of advantages for low-cost manufacturing, ease of automation, and instrument development to enable applications in biomarker validation and medical diagnosis.
We report a method for the sensitive measurement of genomic DNA based on the direct detection of single molecules of DNA in arrays of femtoliter wells. The method begins by generating short fragments of DNA from large, double-stranded molecules of genomic DNA using either restriction enzymes or sonication. Single-stranded fragments are then generated by melting the duplex, and these fragments are hybridized to complementary biotinylated detection probes and capture probes on paramagnetic beads. The resulting DNA complexes are then labeled with an enzyme (streptavidin-β-galactosidase), and single enzymes associated with these complexes on beads are detected in single molecule arrays (Simoa). DNA concentration is quantified by determining the average number of enzymes per bead via Poisson statistics (digital) or the average bead intensity (analog). The Simoa DNA assay was used to detect genomic DNA purified from S. aureus with an average limit of detection (LOD) of 0.07 fM, or 2100 DNA molecules per 50 μL sample. We used this assay to detect S. aureus spiked into (a) whole blood, with an average LOD of 1100 bacteria per 25 μL sample (0.074 fM), and (b) water from the Charles River, with an LOD of 1300 bacteria per 50 μL sample (0.042 fM). Bacteria were detected in river water without prior purification of DNA. The Simoa DNA assay, which directly detects target DNA molecules without molecular replication, is an attractive alternative to existing sensitive DNA detection technologies that rely on amplification using polymerases, such as the polymerase chain reaction (PCR).
Nucleic acid amplification techniques have become the mainstay for ultimate sensitivity for detecting low levels of virus, including human immunodeficiency virus (HIV). As a sophisticated technology with relative expensive reagents and instrumentation, adoption of nucleic acid testing (NAT) can be cost inhibited in settings in which access to extreme sensitivity could be clinically advantageous for detection of acute infection. A simple low cost digital immunoassay was developed for the p24 capsid protein of HIV based on trapping enzyme-labeled immunocomplexes in high-density arrays of femtoliter microwells and constraining the diffusion of the enzyme-substrate reaction. The digital immunoassay was evaluated for analytical sensitivity for HIV capsid protein p24, and compared with commercially available NAT methods and immunoassays for p24, including 4th-generation antibody/antigen combo assays, for early detection of HIV in infected individuals. The digital immunoassay was found to exhibit 2000-3000-fold greater analytical sensitivity than conventional immunoassays reactive for p24, and comparable sensitivity to NAT methods. Assaying serial samples from 10 HIV-infected individuals, the digital immunoassay detected acute HIV infection as early as NAT methods, and 7-10 days earlier than conventional immunoassays. Comparison of assay results between the digital immunoassay and a quantitative NAT method from HIV infected serum exhibited a linear correlation R(2)>0.99. The data indicate that by constraining diffusion of the signal generation step of a simple sandwich immunoassay and enabling the digital counting of immunocomplexes, dramatic improvements in sensitivity to virus can be obtained to match the sensitivity of NAT at a fraction of the cost.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.