Background CORKNOT® facilitates a reduction in cardiopulmonary bypass (CPB) time, aortic cross clamp (ACC) time and operative time, but reported to be associated with other complications. We aim to quantify the incidence of valvular complications related to CORKNOT® and determine the feasibility of its use between different valvular surgeries. Methods Patients who underwent heart valve repair or replacement surgery via the use of automated titanium suture fasteners (CORKNOT®) in a tertiary care hospital were included in the study. This single-centre retrospective study was conducted on 132 patients between January 2016 and June 2018. Results In our study, the overall mean operative time was 320.0 ± 97.0 min, mean CPB time was 171.4 ± 76.0 min and the calculated mean ACC time was 105.9 ± 54.0 min. Fifty-eight patients (43.9%) underwent minimally invasive valve replacement or repair surgery and 66 patients (50.0%) underwent concomitant procedures. A total of 157 valves were operated on, with 112 (84.8%) single valve surgeries, 15 (11.4%) double valve surgeries and 5 (3.8%) triple valve surgeries. After reviewed by the cardiologist blinded towards the study, we report trivial and/or mild paravalvular leak (PVL) in immediate post-operative echocardiography was found in 1 (1.01%) patients. There were no reported cases of valvular thrombosis, leaflet perforation, device dislodgement or embolization, moderate and/or severe PVL during hospitalization and follow-up echocardiography within 1 year. Single mitral valve and aortic surgeries had comparable incidences of post surgical complications. Conclusion We conclude the feasibility of CORKNOT® utilisation in mitral and aortic valve surgeries. Additionally, incidence of CORKNOT® related complications in heart valve repair or replacement surgery is less usual in our setting than previously reported. These results motivate the use of CORKNOT® as a valid alternative with complete commitment.
Background: CORKNOT® facilitates a reduction in cardiopulmonary bypass (CPB) time, aortic cross clamp (ACC) time and operative time, but reported to be associated with other complications. We aim to quantify the incidence of valvular complications related to CORKNOT® and determine the feasibility of its use between different valvular surgeries. Methods: Patients who underwent heart valve repair or replacement surgery via the use of automated titanium suture fasteners (CORKNOT®) in a tertiary care hospital were included in the study. This single-centre retrospective study was conducted on 136 patients between January 2016 and June 2018. Results: In our study, the mean operative time was 320.0 ± 97.0 min, mean CPB time was 171.4 ± 76.0 min and the calculated mean ACC time was 105.9 ± 54.0 min. 58 patients (43.9%) underwent minimally invasive valve replacement or repair surgery and 66 patients (50.0%) underwent concomitant procedures. A total of 157 valves were operated on, with 112 (84.8%) single valve surgeries, 15 (11.4%) double valve surgeries and 5 (3.8%) triple valve surgeries. The incidence of moderate and/or severe paravalvular leak (PVL) in immediate post-operative echocardiography was found in 7 (5.3%) patients. There were no reported cases of valvular thrombosis leaflet perforation, device dislodgement or embolization during follow-up echocardiography. Single mitral valve and aortic surgeries had comparable incidences of valvular complications. Conclusion: We conclude the feasibility of CORKNOT® utilisation in mitral and aortic valve surgeries. Additionally, incidence of CORKNOT® related complications in heart valve repair or replacement surgery is less usual in our setting than previously reported. These results motivate the use of CORKNOT® as a valid alternative with complete commitment.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.