Aims Due to bioprosthetic valve degeneration, aortic valve-in-valve (ViV) procedures are increasingly performed. There are no data on long-term outcomes after aortic ViV. Our aim was to perform a large-scale assessment of long-term survival and reintervention after aortic ViV. Methods and results A total of 1006 aortic ViV procedures performed more than 5 years ago [mean age 77.7 ± 9.7 years; 58.8% male; median STS-PROM score 7.3% (4.2–12.0)] were included in the analysis. Patients were treated with Medtronic self-expandable valves (CoreValve/Evolut, Medtronic Inc., Minneapolis, MN, USA) (n = 523, 52.0%), Edwards balloon-expandable valves (EBEV, SAPIEN/SAPIEN XT/SAPIEN 3, Edwards Lifesciences, Irvine, CA, USA) (n = 435, 43.2%), and other devices (n = 48, 4.8%). Survival was lower at 8 years in patients with small-failed bioprostheses [internal diameter (ID) ≤ 20 mm] compared with those with large-failed bioprostheses (ID > 20 mm) (33.2% vs. 40.5%, P = 0.01). Independent correlates for mortality included smaller-failed bioprosthetic valves [hazard ratio (HR) 1.07 (95% confidence interval (CI) 1.02–1.13)], age [HR 1.21 (95% CI 1.01–1.45)], and non-transfemoral access [HR 1.43 (95% CI 1.11–1.84)]. There were 40 reinterventions after ViV. Independent correlates for all-cause reintervention included pre-existing severe prosthesis–patient mismatch [subhazard ratio (SHR) 4.34 (95% CI 1.31–14.39)], device malposition [SHR 3.75 (95% CI 1.36–10.35)], EBEV [SHR 3.34 (95% CI 1.26–8.85)], and age [SHR 0.59 (95% CI 0.44–0.78)]. Conclusions The size of the original failed valve may influence long-term mortality, and the type of the transcatheter valve may influence the need for reintervention after aortic ViV.
Background: Stroke remains one of the most devastating complications of transcatheter aortic valve implantation (TAVI). The aim of this study was to identify the incidence, timing, temporal trends, and predictors of stroke after TAVI and evaluate the outcomes of patients with stroke. Methods and Results: The CENTER-Collaboration is an international collaboration consisting of 3 national registries and 7 local registries or prospective clinical trials, selected through a systematic review. Accordingly, a total of 10 982 patients undergoing transfemoral TAVI between 2007 and 2018 were included in the current patient-level pooled analyses. A total of 261 patients (2.4%) experienced stroke during the first month after TAVI. The median time between TAVI and stroke was 1 day (interquartile range, 0–6 days). The stroke rate was comparable in procedures performed in the early years of TAVI (2007–2012) to those in the more recent years of TAVI (2013–2018; both 2.4%; P =1.0). Independent predictors of stroke at 30 days were a history of cerebrovascular events (odds ratio, 2.2; 95% CI, 1.4–3.6; P =0.0012) and a glomerular filtration rate of <30 mL/min per 1.73 m 2 (odds ratio, 1.7; 95% CI, 1.0–2.8; P =0.05). Stroke occurring within the first 30 days after TAVI was associated with a 6-fold increase of 30-day mortality (odds ratio, 6.0; 95% CI, 4.4–8.1; P <0.001). Moreover, patients with stroke more frequently had documented new-onset atrial fibrillation (16% versus 3%; P <0.001) and major or life-threatening bleedings (12% versus 7%; P =0.002) at 30-day follow-up. Conclusions: In this large, global, patient-level analysis, the incidence of stroke after transfemoral TAVI was 2.4%. Prior cerebrovascular events and a low glomerular filtration rate independently predicted the occurrence of stroke after TAVI. The occurrence of stroke after TAVI was associated with a strikingly 6-fold increase of 30-day mortality; additionally, there was a 5-fold higher rate of new-onset atrial fibrillation in patients with stroke. Clinical Trial Registration: URL: https://www.clinicaltrials.gov . Unique identifier: NCT03588247.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.