A 77-year-old woman with liver cirrhosis was admitted to our hospital for marked hemorrhage in her ileal conduit stoma. She had a history of cystectomy and urinary diversion for bladder carcinoma 2 years ago. Contrast-enhanced CT demonstrated varices in the ileal conduit stoma. We accessed the varices via a recanalized paraumbilical vein to avoid pain from the transhepatic approach, and selectively embolized the varices with N-butyl cyanoacrylate (NBCA). We consider antegrade embolization of ileal conduit stomal varices with NBCA to be effective and feasible. Access via a paraumbilical vein is a useful alternative to the transhepatic approach.
A 48-year-old woman with alcoholic liver cirrhosis was admitted to our hospital because of hematochezia and severe anemia. She had been hospitalized many times over the past year for hematochezia of unknown etiology. Contrast-enhanced CT demonstrated ileal varices, which were fed by several ileal veins. These feeding veins were selectively embolized with N-butyl cyanoacrylate (NBCA) via a recanalized paraumbilical vein. The paraumbilical vein instead of the portal vein was punctured to decrease the risk of bleeding complications because she had coagulopathy and ascites. We consider antegrade embolization of ileal varices with NBCA to be a feasible and effective treatment. Access via a paraumbilical vein is an alternative to the transhepatic approach.Level of Evidence Level V, case report.
A 77-year-old man was transferred to our hospital for endoscopically uncontrollable active bleeding from a duodenal ulcer. Soon after his arrival, he became hemodynamically unstable and resuscitative endovascular balloon occlusion of the aorta was performed using a 7-F aortic occlusion balloon catheter (Rescue Balloon; Tokai Medical Products, Aichi, Japan). He became hemodynamically stable and was transferred to the CT room. CT demonstrated that the distal part of the catheter shaft had made a loop in the aorta and the balloon was located at the level of the upper abdomen. We consider the low-profile occlusion balloon catheter to be less rigid than large ones, and care should be taken to prevent balloon migration and catheter shaft bending.
A 69-year-old man was transferred to our hospital for massive hemorrhage from a right hepatic artery pseudoaneurysm 5 months after surgery for gastric cancer. Stent-graft placement was planned to avoid fatal hepatic infarction, and a guiding sheath was advanced deeply into the tortuous and stenotic right hepatic artery beyond the pseudoaneurysm for safe deployment of a stent-graft. However, this advancement caused arterial dissection of the right hepatic artery. After the guiding sheath was pulled back, a Viabahn stent-graft was successfully advanced over a guidewire to exclude the pseudoaneurysm. We consider that a Viabahn stent-graft is more flexible than a guiding sheath and that advancing a Viabahn stent-graft directly from a proximally placed guiding sheath is safer than advancing a guiding sheath into a tortuous and stenotic abdominal artery.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.