Background: Recent advances in technology have enabled the development of head impact sensors, which provide a unique opportunity for sports medicine researchers to study head kinematics in contact sports. Studies have suggested that video or observer confirmation of head impact sensor data is required to remove false positives. In addition, manufacturer filtering algorithms may be ineffective in identifying true positives and removing true negatives. Purpose: To (1) identify the percentage of video-confirmed events recorded by headband-mounted sensors in high school soccer through video analysis, overall and by sex; (2) compare video-confirmed events with the classification by the manufacturer filtering algorithms; and (3) quantify and compare the kinematics of true- and false-positive events. Study Design: Cohort study; Level of evidence, 2. Methods: Adolescent female and male soccer teams were instrumented with headband-mounted impact sensors (SIM-G; Triax Technologies) during games over 2 seasons of suburban high school competition. Sensor data were sequentially reduced to remove events recorded outside of game times, associated with players not on the pitch (ie, field) and players outside the field of view of the camera. With video analysis, the remaining sensor-recorded events were identified as an impact event, trivial event, or nonevent. The mechanisms of impact events were identified. The classifications of sensor-recorded events by the SIM-G algorithm were analyzed. Results: A total of 6796 sensor events were recorded during scheduled varsity game times, of which 1893 (20%) were sensor-recorded events associated with players on the pitch in the field of view of the camera during verified game times. Most video-confirmed events were impact events (n = 1316, 70%), followed by trivial events (n = 396, 21%) and nonevents (n = 181, 10%). Female athletes had a significantly higher percentage of trivial events and nonevents with a significantly lower percentage of impact events. Most impact events were head-to-ball impacts (n = 1032, 78%), followed by player contact (n = 144, 11%) and falls (n = 129, 10%) with no significant differences between male and female teams. The SIM-G algorithm correctly identified 70%, 52%, and 66% of video-confirmed impact events, trivial events, and nonevents, respectively. Conclusion: Video confirmation is critical to the processing of head impact sensor data. Percentages of video-confirmed impact events, trivial events, and nonevents vary by sex in high school soccer. Current manufacturer filtering algorithms and magnitude thresholds are ineffective at correctly classifying sensor-recorded events and should be used with caution.
IMPORTANCE Concussion diagnosis remains clinical, without objective diagnostic tests available for adolescents. Known deficits in visual accommodation and autonomic function after concussion make the pupillary light reflex (PLR) a promising target as an objective physiological biomarker for concussion.OBJECTIVE To determine the potential utility of PLR metrics as physiological biomarkers for concussion.DESIGN, SETTING, AND PARTICIPANTS Prospective cohort of adolescent athletes between ages 12 and 18 years recruited between August 1, 2017, and December 31, 2018. The study took place at a specialty concussion program and private suburban high school and included healthy control individuals (n = 134) and athletes with a diagnosis of sport-related concussion (SRC) (n = 98). Analysis was completed June 30, 2020. EXPOSURES Sports-related concussion and pupillometry assessments.MAIN OUTCOMES AND MEASURES Pupillary light reflex metrics (maximum and minimum pupillary diameter, peak and average constriction/dilation velocity, percentage constriction, and time to 75% pupillary redilation [T75]).RESULTS Pupillary light reflex metrics of 134 healthy control individuals and 98 athletes with concussion were obtained a median of 12.0 days following injury (interquartile range [IQR], 5.0-18.0 days). Eight of 9 metrics were significantly greater among athletes with concussion after Bonferroni correction (maximum pupil diameter: 4.83 mm vs 4.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.