Checkpoint inhibitor pneumonitis (CIP) is an immunerelated adverse event that can occur after initiation of anti-programmed death 1/programmed death ligand 1 immune checkpoint inhibitor (ICI) therapy for the treatment of multiple malignancies, including NSCLC. However, the incidence of CIP has not been previously examined in a population that included both trial-enrolled and non-trialenrolled patients with advanced NSCLC. Furthermore, risk factors and other clinical characteristics associated with CIP severity are not known. In this study, we retrospectively examined clinical characteristics, incidence, and risk factors for CIP in a cohort of 205 patients with NSCLC, all of whom received anti-programmed death 1/programmed death ligand 1 ICIs. Our results demonstrate a higher incidence of CIP (19%) than previously reported in clinical trials (3%-5%). Our data also suggest that tumor histologic type may be a risk factor for CIP development. We observed a wide range of time to onset of CIP (median 82 days), with high morbidity and mortality associated with higher-grade CIP regardless of degree of immunosuppression. Our data provide new insight into the epidemiology and clinical
Rationale: Advanced bronchoscopy techniques such as electromagnetic navigation (EMN) have been studied in clinical trials, but there are no randomized studies comparing EMN with standard bronchoscopy.Objectives: To measure and identify the determinants of diagnostic yield for bronchoscopy in patients with peripheral lung lesions. Secondary outcomes included diagnostic yield of different sampling techniques, complications, and practice pattern variations.Methods: We used the AQuIRE (ACCP Quality Improvement Registry, Evaluation, and Education) registry to conduct a multicenter study of consecutive patients who underwent transbronchial biopsy (TBBx) for evaluation of peripheral lesions.Measurements and Main Results: Fifteen centers with 22 physicians enrolled 581 patients. Of the 581 patients, 312 (53.7%) had a diagnostic bronchoscopy. Unadjusted for other factors, the diagnostic yield was 63.7% when no radial endobronchial ultrasound (r-EBUS) and no EMN were used, 57.0% with r-EBUS alone, 38.5% with EMN alone, and 47.1% with EMN combined with r-EBUS. In multivariate analysis, peripheral transbronchial needle aspiration (TBNA), larger lesion size, nonupper lobe location, and tobacco use were associated with increased diagnostic yield, whereas EMN was associated with lower diagnostic yield. Peripheral TBNA was used in 16.4% of cases. TBNA was diagnostic, whereas TBBx was nondiagnostic in 9.5% of cases in which both were performed. Complications occurred in 13 (2.2%) patients, and pneumothorax occurred in 10 (1.7%) patients. There were significant differences between centers and physicians in terms of case selection, sampling methods, and anesthesia. Medical center diagnostic yields ranged from 33 to 73% (P = 0.16).Conclusions: Peripheral TBNA improved diagnostic yield for peripheral lesions but was underused. The diagnostic yields of EMN and r-EBUS were lower than expected, even after adjustment.
Evidence on the technical aspects of EBUS-TBNA varies in strength but is satisfactory in certain areas to guide clinicians on the best conditions to perform EBUS-guided tissue sampling. Additional research is needed to enhance our knowledge regarding the optimal performance of this effective procedure.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.