IMPORTANCE An intraoperative higher level of positive end-expiratory positive pressure (PEEP) with alveolar recruitment maneuvers improves respiratory function in obese patients undergoing surgery, but the effect on clinical outcomes is uncertain. OBJECTIVE To determine whether a higher level of PEEP with alveolar recruitment maneuvers decreases postoperative pulmonary complications in obese patients undergoing surgery compared with a lower level of PEEP. DESIGN, SETTING, AND PARTICIPANTS Randomized clinical trial of 2013 adults with body mass indices of 35 or greater and substantial risk for postoperative pulmonary complications who were undergoing noncardiac, nonneurological surgery under general anesthesia. The trial was conducted at 77 sites in 23 countries from July 2014-February 2018; final follow-up: May 2018. INTERVENTIONS Patients were randomized to the high level of PEEP group (n = 989), consisting of a PEEP level of 12 cm H 2 O with alveolar recruitment maneuvers (a stepwise increase of tidal volume and eventually PEEP) or to the low level of PEEP group (n = 987), consisting of a PEEP level of 4 cm H 2 O. All patients received volume-controlled ventilation with a tidal volume of 7 mL/kg of predicted body weight. MAIN OUTCOMES AND MEASURES The primary outcome was a composite of pulmonary complications within the first 5 postoperative days, including respiratory failure, acute respiratory distress syndrome, bronchospasm, new pulmonary infiltrates, pulmonary infection, aspiration pneumonitis, pleural effusion, atelectasis, cardiopulmonary edema, and pneumothorax. Among the 9 prespecified secondary outcomes, 3 were intraoperative complications, including hypoxemia (oxygen desaturation with SpO 2 Յ92% for >1 minute). RESULTS Among 2013 adults who were randomized, 1976 (98.2%) completed the trial (mean age, 48.8 years; 1381 [69.9%] women; 1778 [90.1%] underwent abdominal operations). In the intention-to-treat analysis, the primary outcome occurred in 211 of 989 patients (21.3%) in the high level of PEEP group compared with 233 of 987 patients (23.6%) in the low level of PEEP group (difference, −2.3% [95% CI, −5.9% to 1.4%]; risk ratio, 0.93 [95% CI, 0.83 to 1.04]; P = .23). Among the 9 prespecified secondary outcomes, 6 were not significantly different between the high and low level of PEEP groups, and 3 were significantly different, including fewer patients with hypoxemia (5.0% in the high level of PEEP group vs 13.6% in the low level of PEEP group; difference, −8.6% [95% CI, −11.1% to 6.1%]; P < .001). CONCLUSIONS AND RELEVANCE Among obese patients undergoing surgery under general anesthesia, an intraoperative mechanical ventilation strategy with a higher level of PEEP and alveolar recruitment maneuvers, compared with a strategy with a lower level of PEEP, did not reduce postoperative pulmonary complications.
Background: Electrical impedance tomography (EIT) with indicator dilution may be clinically useful to measure relative lung perfusion, but there is limited information on the performance of this technique. Methods: Thirteen pigs (50e66 kg) were anaesthetised and mechanically ventilated. Sequential changes in ventilation were made: (i) right-lung ventilation with left-lung collapse, (ii) two-lung ventilation with optimised PEEP, (iii) two-lung ventilation with zero PEEP after saline lung lavage, (iv) two-lung ventilation with maximum PEEP (20/25 cm H 2 O to achieve peak airway pressure 45 cm H 2 O), and (v) two-lung ventilation under unilateral pulmonary artery occlusion. Relative lung perfusion was assessed with EIT and central venous injection of saline 3%, 5%, and 10% (10 ml) during breath holds. Relative perfusion was determined by positron emission tomography (PET) using 68 Gallium-labelled microspheres. EIT and PET were compared in eight regions of equal ventro-dorsal height (right, left, ventral, mid-ventral, mid-dorsal, and dorsal), and directional changes in regional perfusion were determined. Results: Differences between methods were relatively small (95% of values differed by less than 8.7%, 8.9%, and 9.5% for saline 10%, 5%, and 3%, respectively). Compared with PET, EIT underestimated relative perfusion in dependent, and overestimated it in non-dependent, regions. EIT and PET detected the same direction of change in relative lung perfusion in 68.9e95.9% of measurements. Conclusions: The agreement between EIT and PET for measuring and tracking changes of relative lung perfusion was satisfactory for clinical purposes. Indicator-based EIT may prove useful for measuring pulmonary perfusion at bedside.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.