Cardiopulmonary bypass surgical techniques that allow a surgeon to operate on the infant's heart use an extracorporeal circuit consisting of a pump, oxygenator, arterial and venous reservoirs, cannulae, an arterial filter, and tubing. The extracorporeal technique currently used in infants and neonates is sometimes associated with neurologic damage. We are developing a modified cardiopulmonary bypass system for neonates that has been tested in vitro and in one animal in vivo. Unlike other extracorporeal circuits which use steady flow, this system utilizes pulsatile flow, a low prime volume (500 ml) and a closed circuit. During in vitro experiments, the pseudo patient's mean arterial pressure was kept constant at 40 mmHg and the extracorporeal circuit pressure did not exceed a mean pressure of 200 mmHg. In our single in vivo experiment, the primary objective was to determine whether physiologic pulsatility with a 10 F (3.3 mm) aortic cannula could be achieved. The results suggest that this is possible.
Background Clinical complexity is increasingly prevalent among patients with atrial fibrillation (AF). The ‘Atrial fibrillation Better Care’ (ABC) pathway approach has been proposed to streamline a more holistic and integrated approach to AF care; however, there are limited data on its usefulness among clinically complex patients. We aim to determine the impact of ABC pathway in a contemporary cohort of clinically complex AF patients. Methods From the ESC-EHRA EORP-AF General Long-Term Registry, we analysed clinically complex AF patients, defined as the presence of frailty, multimorbidity and/or polypharmacy. A K-medoids cluster analysis was performed to identify different groups of clinical complexity. The impact of an ABC-adherent approach on major outcomes was analysed through Cox-regression analyses and delay of event (DoE) analyses. Results Among 9966 AF patients included, 8289 (83.1%) were clinically complex. Adherence to the ABC pathway in the clinically complex group reduced the risk of all-cause death (adjusted HR [aHR]: 0.72, 95%CI 0.58–0.91), major adverse cardiovascular events (MACEs; aHR: 0.68, 95%CI 0.52–0.87) and composite outcome (aHR: 0.70, 95%CI: 0.58–0.85). Adherence to the ABC pathway was associated with a significant reduction in the risk of death (aHR: 0.74, 95%CI 0.56–0.98) and composite outcome (aHR: 0.76, 95%CI 0.60–0.96) also in the high-complexity cluster; similar trends were observed for MACEs. In DoE analyses, an ABC-adherent approach resulted in significant gains in event-free survival for all the outcomes investigated in clinically complex patients. Based on absolute risk reduction at 1 year of follow-up, the number needed to treat for ABC pathway adherence was 24 for all-cause death, 31 for MACEs and 20 for the composite outcome. Conclusions An ABC-adherent approach reduces the risk of major outcomes in clinically complex AF patients. Ensuring adherence to the ABC pathway is essential to improve clinical outcomes among clinically complex AF patients.
Aims The 4S-AF classification scheme comprises of four domains: stroke risk (St), symptoms (Sy), severity of atrial fibrillation (AF) burden (Sb), and substrate (Su). We sought to examine the implementation of the 4S-AF scheme in the EORP-AF General Long-Term Registry and compare outcomes in AF patients according to the 4S-AF-led decision-making process. Methods and results Atrial fibrillation patients from 250 centres across 27 European countries were included. A 4S-AF score was calculated as the sum of each domain with a maximum score of 9. Of 6321 patients, 8.4% had low (St), 47.5% EHRA I (Sy), 40.5% newly diagnosed or paroxysmal AF (Sb), and 5.1% no cardiovascular risk factors or left atrial enlargement (Su). Median follow-up was 24 months. Using multivariable Cox regression analysis, independent predictors of all-cause mortality were (St) [adjusted hazard ratio (aHR) 8.21, 95% confidence interval (CI): 2.60–25.9], (Sb) (aHR 1.21, 95% CI: 1.08–1.35), and (Su) (aHR 1.27, 95% CI: 1.14–1.41). For CV mortality and any thromboembolic event, only (Su) (aHR 1.73, 95% CI: 1.45–2.06) and (Sy) (aHR 1.29, 95% CI: 1.00–1.66) were statistically significant, respectively. None of the domains were independently linked to ischaemic stroke or major bleeding. Higher 4S-AF score was related to a significant increase in all-cause mortality, CV mortality, any thromboembolic event, and ischaemic stroke but not major bleeding. Treatment of all 4S-AF domains was associated with an independent decrease in all-cause mortality (aHR 0.71, 95% CI: 0.55–0.92). For each 4S-AF domain left untreated, the risk of all-cause mortality increased substantially (aHR 1.35, 95% CI: 1.16–1.56). Conclusion Implementation of the novel 4S-AF scheme is feasible, and treatment decisions based on this scheme improve mortality rates in AF.
In general, patients > or = 80 years of age who meet current indications for ICD implantation live sufficiently long to warrant device implantation based on anticipated survival alone. However, those with an EF < or = 20% have a markedly elevated 1-year mortality with no observed increase in appropriate ICD therapy, thus reducing the benefit of device implantation in this population.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.