Study Design: Retrospective analysis. Level of evidence III. Objectives: To describe the results after a minimum 1-year follow-up in patients treated with percutaneous discoplasty (PD), a minimally invasive technique to treat low back pain in elderly patients with advanced degenerative disc disease. The procedure consists in improving stability by injecting bone cement in a severely degenerated pneumodisc. There are few reports in the literature about this technique. Methods: Fifty-four patients with advanced disc disease with/without degenerative scoliosis treated with PD with at least 1 year follow-up were studied, variables included clinical (visual analogue scale [VAS] and Owestry Disability Index [ODI]) and radiological parameters (lumbar lordosis and Cobb angle), as well as hospital length of stay and complications. Results: At 1-year postoperation, significant pain reduction (VAS: preoperative 7.8 ± 0.90; postoperative 4.4 ± 2.18) and improvement in the ODI (preoperative 62 ± 7.12; postoperative 36.2 ± 15.47) were observed with partial correction of radiological parameters (5° mean increase in lumbar lordosis and decrease in Cobb angle). Mean surgical time was 38 minutes, and the mean length of hospital stay was 1.2 days. Conclusion: PD, currently not a very well-known technique, appears to be—at least in the short-term follow-up—an effective treatment option in selected cases with low back pain due to advanced degenerative disc disease.
Purpose The management of cervical facet dislocation injuries remains controversial. The main purpose of this investigation was to identify whether a surgeon's geographic location or years in practice influences their preferred management of traumatic cervical facet dislocation injuries. Methods A survey was sent to 272 AO Spine members across all geographic regions and with a variety of practice experience. The survey included clinical case scenarios of cervical facet dislocation injuries and asked responders to select preferences among various diagnostic and management options. Results A total of 189 complete responses were received. Over 50% of responding surgeons in each region elected to initiate management of cervical facet dislocation injuries with an MRI, with 6 case exceptions. Overall, there was considerable agreement between American and European responders regarding management of these injuries, with only 3 cases exhibiting a significant difference. Additionally, results also exhibited considerable management agreement between those with ≤ 10 and > 10 years of practice experience, with only 2 case exceptions noted. Conclusion More than half of responders, regardless of geographical location or practice experience, identified MRI as a screening imaging modality when managing cervical facet dislocation injuries, regardless of the status of the spinal cord and prior to any additional intervention. Additionally, a majority of surgeons would elect an anterior approach for the surgical management of these injuries. The study found overall agreement in management preferences of cervical facet dislocation injuries around the globe.
Study Design: Diagnostic study, level of evidence III. Objectives: Low back pain is a common cause of disability among elderly patients. Percutaneous discoplasty has been developed as a tool to treat degenerative disease when conservative management is not successful. Indications for this procedure include low back pain and the presence of vacuum phenomenon. The objective of this study was to describe a new classification of vacuum phenomenon based on computed tomography scan in order to improve the indications for percutaneous discoplasty. Methods: We developed a classification of vacuum phenomenon based on computed tomography scan images. We describe 3 types of vacuum based on the relationship between vacuum and the superior/inferior endplates and 2 subtypes based on the presence of significant subchondral sclerosis. A validation study was conducted selecting 10 orthopedic residents with spine surgery training to analyze 25 vacuum scenarios. Inter- and intraobserver reliabilities were assessed through the Fleiss’s and Cohen’s kappa statistics, respectively. Results: The overall Fleiss’s κ value for interobserver reliability was 0.85 (95% CI 0.82-0.86) in the first reading and 0.93 (95% CI 0.92-0.95) in the second reading. Cohen’s κ for intraobserver reliability was 0.88 (95% CI 0.77-0.99). Conclusion: The new classification has shown almost perfect inter- and intraobserver reliabilities for grading the vacuum phenomenon and could be an important tool to improve the indications for percutaneous cement discoplasty.
Purpose To validate the AO Spine Subaxial Injury Classification System with participants of various experience levels, subspecialties, and geographic regions. Methods A live webinar was organized in 2020 for validation of the AO Spine Subaxial Injury Classification System. The validation consisted of 41 unique subaxial cervical spine injuries with associated computed tomography scans and key images. Intraobserver reproducibility and interobserver reliability of the AO Spine Subaxial Injury Classification System were calculated for injury morphology, injury subtype, and facet injury. The reliability and reproducibility of the classification system were categorized as slight (ƙ = 0–0.20), fair (ƙ = 0.21–0.40), moderate (ƙ = 0.41–0.60), substantial (ƙ = 0.61–0.80), or excellent (ƙ = > 0.80) as determined by the Landis and Koch classification. Results A total of 203 AO Spine members participated in the AO Spine Subaxial Injury Classification System validation. The percent of participants accurately classifying each injury was over 90% for fracture morphology and fracture subtype on both assessments. The interobserver reliability for fracture morphology was excellent (ƙ = 0.87), while fracture subtype (ƙ = 0.80) and facet injury were substantial (ƙ = 0.74). The intraobserver reproducibility for fracture morphology and subtype were excellent (ƙ = 0.85, 0.88, respectively), while reproducibility for facet injuries was substantial (ƙ = 0.76). Conclusion The AO Spine Subaxial Injury Classification System demonstrated excellent interobserver reliability and intraobserver reproducibility for fracture morphology, substantial reliability and reproducibility for facet injuries, and excellent reproducibility with substantial reliability for injury subtype.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.