This paper evaluates the relation between Alcohol Withdrawal Syndrome tremors in the left and right hands of patients. By analyzing 122 recordings from 61 patients in emergency departments, we found a weak relationship between the left and right hand tremor frequencies (correlation coefficient of 0.63). We found a much stronger relationship between the expert physician tremor ratings (on CIWA-Ar 0-7 scale) of the two hands, with a correlation coefficient of 0.923. Next, using a smartphone to collect the tremor data and using a previously developed model for obtaining estimated tremor ratings, we also found a strong correlation (correlation coefficient of 0.852) between the estimates of each hand. Finally, we evaluated different methods of combining the data from the two hands for obtaining a single tremor rating estimate, and found that simply averaging the tremor ratings of the two hands results in the lowest tremor estimate error (an RMSE of 0.977). Looking at the frequency dependence of this error, we found that higher frequency tremors had a much lower estimation error (an RMSE of 1.102 for tremors with frequencies in the 3-6Hz range as compared to 0.625 for tremors with frequencies in the 7-10Hz range).
In this paper, we propose a signal processing method of assessing the severity tremors caused by alcohol withdrawal (AW) syndrome. We have developed an iOS application to calculate the Clinical Institute Withdrawal Assessment (CIWA) score which captures iPod movements using the built-in accelerometer in order to reliably estimate the tremor severity component of the score. We report on the characteristics of AW tremor, the accuracy of electronic assessment of tremor compared to expert clinician assessment, and the potential for using signal processing assessment to differentiate factitious from real tremor in patients seen in the emergency department, as well as in nurses mimicking a tremor. Our preliminary results are based on 84 recordings from 61 subjects (49 patients, 12 nurses). In general we found a linear relationship between energy measured by the accelerometer (in the 4.4-10 Hz range) and the expert rating of tremor severity. Additionally, we demonstrate that 75% of the recordings from patients with actual AW syndrome had a mean peak frequency higher than 7 Hz whereas only 17% of the nurses' factitious tremors were above 7 Hz, suggesting that tremor above 7 Hz could be a potential discriminator of real versus factitious tremors.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.