Proton beams are a promising tool for the improvement of radiotherapy of cancer, and compact laserdriven proton radiation (LDPR) is discussed as an alternative to established large-scale technology facilitating wider clinical use. Yet, clinical use of LDPR requires substantial development in reliable beam generation and transport, but also in dosimetric protocols as well as validation in radiobiological studies. Here, we present the first dose-controlled direct comparison of the radiobiological effectiveness of intense proton pulses from a laser-driven accelerator with conventionally generated continuous proton beams, demonstrating a first milestone in translational research. Controlled dose delivery, precisely online and offline monitored for each out of *4,000 pulses, resulted in an unprecedented relative dose uncertainty of below 10 %, using approaches scalable to the next translational step toward radiotherapy application.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.