Background-Computed tomography (CT) is increasingly used to detect coronary artery disease, but the evaluation of stenoses is often uncertain. Perfusion imaging has an established role in detecting ischemia and guiding therapy. Hybrid positron emission tomography (PET)/CT allows combination angiography and perfusion imaging in short, quantitative, low-radiation-dose protocols. Methods and Results-We enrolled 107 patients with an intermediate (30% to 70%) pretest likelihood of coronary artery disease. All patients underwent PET/CT (quantitative PET with 15 O-water and CT angiography), and the results were compared with the gold standard, invasive angiography, including measurement of fractional flow reserve when appropriate. Although PET and CT angiography alone both demonstrated 97% negative predictive value, CT angiography alone was suboptimal in assessing the severity of stenosis (positive predictive value, 81%). Perfusion imaging alone could not always separate microvascular disease from epicardial stenoses, but hybrid PET/CT significantly improved this accuracy to 98%. The radiation dose of the combined PET and CT protocols was 9.3 mSv (86 patients) with prospective triggering and 21.8 mSv (21 patients)
Background-The choice of imaging techniques in patients with suspected coronary artery disease (CAD) varies between countries, regions, and hospitals. This prospective, multicenter, comparative effectiveness study was designed to assess the relative accuracy of commonly used imaging techniques for identifying patients with significant CAD. Methods and Results-A total of 475 patients with stable chest pain and intermediate likelihood of CAD underwent coronary computed tomographic angiography and stress myocardial perfusion imaging by single photon emission computed tomography or positron emission tomography, and ventricular wall motion imaging by stress echocardiography or cardiac magnetic resonance. If ≥1 test was abnormal, patients underwent invasive coronary angiography. Significant CAD was defined by invasive coronary angiography as >50% stenosis of the left main stem, >70% stenosis in a major coronary vessel, or 30% to 70% stenosis with fractional flow reserve ≤0.8. Significant CAD was present in 29% of patients. In a patient-based analysis, coronary computed tomographic angiography had the highest diagnostic accuracy, the area under the receiver operating characteristics curve being 0.91 (95% confidence interval, 0.88-0.94), sensitivity being 91%, and specificity being 92%. Myocardial perfusion imaging had good diagnostic accuracy (area under the curve, 0.74;
MD; for the Nordic-Baltic PCI Study GroupBackground-It is unknown whether the preferred 1-stent bifurcation stenting approach with stenting of the main vessel (MV) and optional side branch stenting using drug-eluting stents should be finalized by a kissing balloon dilatation (FKBD). Therefore, we compared strategies of MV stenting with and without FKBD. Methods and Results-We randomized 477 patients with a bifurcation lesion to FKBD (nϭ238) or no FKBD (nϭ239) after MV stenting. The primary end point was major adverse cardiac events: cardiac death, non-procedure-related index lesion myocardial infarction, target lesion revascularization, or stent thrombosis within 6 months. The 6-month major adverse cardiac event rates were 2.1% and 2.5% (Pϭ1.00) in the FKBD and no-FKBD groups, respectively. Procedure and fluoroscopy times were longer and more contrast media was needed in the FKBD group than in the no-FKBD group. Three hundred twenty-six patients had a quantitative coronary assessment. At 8 months, the rate of binary (re)stenosis in the entire bifurcation lesion (MV and side branch) was 11.0% versus 17.3% (Pϭ0.11), in the MV was 3.1% versus 2.5% (Pϭ0.68), and in the side branch was 7.9% versus 15.4% (Pϭ0.039) in the FKBD versus no-FKBD groups, respectively. In patients with true bifurcation lesions, the side branch restenosis rate was 7.6% versus 20.0% (Pϭ0.024) in the FKBD and no-FKBD groups, respectively.
Conclusions-MV
Intracoronary BMC therapy is associated with an improvement of global LVEF and neutral effects on arrhythmia risk profile and restenosis of the stented coronary lesions in patients after thrombolytic therapy of STEMI.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.