Objective: The aim of this study was to develop and externally validate the first evidence-based guidelines on minimally invasive pancreas resection (MIPR) before and during the International Evidence-based Guidelines on Minimally Invasive Pancreas Resection (IG-MIPR) meeting in Miami (March 2019). Summary Background Data: MIPR has seen rapid development in the past decade. Promising outcomes have been reported by early adopters from high-volume centers. Subsequently, multicenter series as well as randomized controlled trials were reported; however, guidelines for clinical practice were lacking. Methods: The Scottisch Intercollegiate Guidelines Network (SIGN) methodology was used, incorporating these 4 items: systematic reviews using PubMed, Embase, and Cochrane databases to answer clinical questions, whenever possible in PICO style, the GRADE approach for assessment of the quality of evidence, the Delphi method for establishing consensus on the developed recommendations, and the AGREE-II instrument for the assessment of guideline quality and external validation. The current guidelines are cosponsored by the International Hepato-Pancreato-Biliary Association, the Americas Hepato-Pancreato-Biliary Association, the Asian-Pacific Hepato-Pancreato-Biliary Association, the European-African Hepato-Pancreato-Biliary Association, the European Association for Endoscopic Surgery, Pancreas Club, the Society of American Gastrointestinal and Endoscopic Surgery, the Society for Surgery of the Alimentary Tract, and the Society of Surgical Oncology. Results: After screening 16,069 titles, 694 studies were reviewed, and 291 were included. The final 28 recommendations covered 6 topics; laparoscopic and robotic distal pancreatectomy, central pancreatectomy, pancreatoduodenectomy, as well as patient selection, training, learning curve, and minimal annual center volume required to obtain optimal outcomes and patient safety. Conclusion: The IG-MIPR using SIGN methodology give guidance to surgeons, hospital administrators, patients, and medical societies on the use and outcome of MIPR as well as the approach to be taken regarding this challenging type of surgery.
Background The role of minimally invasive distal pancreatectomy is still unclear, and whether robotic distal pancreatectomy (RDP) offers benefits over laparoscopic distal pancreatectomy (LDP) is unknown because large multicentre studies are lacking. This study compared perioperative outcomes between RDP and LDP. Methods A multicentre international propensity score-matched study included patients who underwent RDP or LDP for any indication in 21 European centres from six countries that performed at least 15 distal pancreatectomies annually (January 2011 to June 2019). Propensity score matching was based on preoperative characteristics in a 1 : 1 ratio. The primary outcome was the major morbidity rate (Clavien–Dindo grade IIIa or above). Results A total of 1551 patients (407 RDP and 1144 LDP) were included in the study. Some 402 patients who had RDP were matched with 402 who underwent LDP. After matching, there was no difference between RDP and LDP groups in rates of major morbidity (14.2 versus 16.5 per cent respectively; P = 0.378), postoperative pancreatic fistula grade B/C (24.6 versus 26.5 per cent; P = 0.543) or 90-day mortality (0.5 versus 1.3 per cent; P = 0.268). RDP was associated with a longer duration of surgery than LDP (median 285 (i.q.r. 225–350) versus 240 (195–300) min respectively; P < 0.001), lower conversion rate (6.7 versus 15.2 per cent; P < 0.001), higher spleen preservation rate (81.4 versus 62.9 per cent; P = 0.001), longer hospital stay (median 8.5 (i.q.r. 7–12) versus 7 (6–10) days; P < 0.001) and lower readmission rate (11.0 versus 18.2 per cent; P = 0.004). Conclusion The major morbidity rate was comparable between RDP and LDP. RDP was associated with improved rates of conversion, spleen preservation and readmission, to the detriment of longer duration of surgery and hospital stay.
Background: Theoretical advantages of robotic surgery compared to conventional laparoscopic surgery include improved instrument dexterity, 3D visualization, and better ergonomics. This systematic review and meta-analysis aimed to determine advantages of robotic surgery over laparoscopic surgery in patients undergoing liver resections. Method: A systematic literature search was conducted for studies comparing robotic assisted or totally laparoscopic liver resection. Meta-analysis of intraoperative (operative time, blood loss, transfusion rate, conversion rate), oncological (R0 resection rates), and postoperative (bile leak, surgical site infection, pulmonary complications, 30-day and 90-day mortality, length of stay, 90-day readmission and reoperation rates) outcomes was performed using a random effects model. Result: Twenty-six non-randomized studies including 2630 patients (950 robotic and 1680 laparoscopic) were included, of which 20% had major robotic liver resection and 14% had major laparoscopic liver resection. Intraoperatively, robotic liver resection was associated with significantly less blood loss (mean: 286 vs 301 mL, p < 0.001) but longer operating time (mean: 281 vs 221 min, p < 0.001). There were no significant differences in conversion rates or transfusion rates between robotic liver resection and laparoscopic liver resection. Postoperatively, there were no significant differences in overall complications, bile leaks, and length of hospital stay between robotic liver resection and laparoscopic liver resection. However, robotic liver resection was associated with significantly lower readmission rates than laparoscopic liver resection (odds ratio: 0.43, p = 0.005). Conclusion: Robotic liver resection appears to offer some advantages compared to conventional laparoscopic surgery, although both techniques appear equivalent. Importantly, the quality of evidence is generally limited to cohort studies and a high-quality randomized trial comparing both techniques is needed.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.