BACKGROUNDPrevious trials have shown that among high-risk patients with aortic stenosis, survival rates are similar with transcatheter aortic-valve replacement (TAVR) and surgical aorticvalve replacement. We evaluated the two procedures in a randomized trial involving intermediate-risk patients. METHODSWe randomly assigned 2032 intermediate-risk patients with severe aortic stenosis, at 57 centers, to undergo either TAVR or surgical replacement. The primary end point was death from any cause or disabling stroke at 2 years. The primary hypothesis was that TAVR would not be inferior to surgical replacement. Before randomization, patients were entered into one of two cohorts on the basis of clinical and imaging findings; 76.3% of the patients were included in the transfemoral-access cohort and 23.7% in the transthoracic-access cohort. RESULTSThe rate of death from any cause or disabling stroke was similar in the TAVR group and the surgery group (P = 0.001 for noninferiority). At 2 years, the Kaplan-Meier event rates were 19.3% in the TAVR group and 21.1% in the surgery group (hazard ratio in the TAVR group, 0.89; 95% confidence interval [CI], 0.73 to 1.09; P = 0.25). In the transfemoralaccess cohort, TAVR resulted in a lower rate of death or disabling stroke than surgery (hazard ratio, 0.79; 95% CI, 0.62 to 1.00; P = 0.05), whereas in the transthoracic-access cohort, outcomes were similar in the two groups. TAVR resulted in larger aortic-valve areas than did surgery and also resulted in lower rates of acute kidney injury, severe bleeding, and new-onset atrial fibrillation; surgery resulted in fewer major vascular complications and less paravalvular aortic regurgitation. CONCLUSIONSIn intermediate-risk patients, TAVR was similar to surgical aortic-valve replacement with respect to the primary end point of death or disabling stroke. (Funded by Edwards Lifesciences; PARTNER 2 ClinicalTrials.gov number, NCT01314313.) a bs tr ac t
Among appropriately selected patients with severe aortic stenosis who were not suitable candidates for surgery, TAVR reduced the rates of death and hospitalization, with a decrease in symptoms and an improvement in valve hemodynamics that were sustained at 2 years of follow-up. The presence of extensive coexisting conditions may attenuate the survival benefit of TAVR. (Funded by Edwards Lifesciences; ClinicalTrials.gov number, NCT00530894.).
Aims To critically review the available transcatheter aortic valve implantation techniques and their results, as well as propose recommendations for their use and development. Methods and results A committee of experts including European Association of Cardio-Thoracic Surgery and European Society of Car-diology representatives met to reach a consensus based on the analysis of the available data obtained with transcath-eter aortic valve implantation and their own experience. The evidence suggests that this technique is feasible and provides haemodynamic and clinical improvement for up to 2 years in patients with severe symptomatic aortic ste-nosis at high risk or with contraindications for surgery. Questions remain mainly concerning safety and long-term durability, which have to be assessed. Surgeons and cardiologists working as a team should select candidates, perform the procedure, and assess the results. Today, the use of this technique should be restricted to high-risk patients or those with contraindications for surgery. However, this may be extended to lower risk patients if the initial promise holds to be true after careful evaluation. * Corresponding authors. Tel: þ33 1 40 25 67 60, Fax: þ33 1 40 25 67 32, Email: alec.vahanian@bch.aphp.fr (A. V.);
Background-The prognosis and treatment of patients with low-flow (LF) severe aortic stenosis are controversial. Methods and Results-The Placement of Aortic Transcatheter Valves (PARTNER) trial randomized patients with severe aortic stenosis to medical management versus transcatheter aortic valve replacement (TAVR; inoperable cohort) and surgical aortic valve replacement versus TAVR (high-risk cohort). Among 971 patients with evaluable echocardiograms (92%), LF (stroke volume index ≤35 mL/m 2 ) was observed in 530 (55%); LF and low ejection fraction (<50%) in 225 (23%); and LF, low ejection fraction, and low mean gradient (<40 mm Hg) in 147 (15%). Two-year mortality was significantly higher in patients with LF compared with those with normal stroke volume index (47% versus 34%; hazard ratio, 1.5; 95% confidence interval, 1.25-1.89; P=0.006). In the inoperable cohort, patients with LF had higher mortality than those with normal flow, but both groups improved with TAVR (46% versus 76% with LF and 38% versus 53% with normal flow; P<0.001). In the high-risk cohort, there was no difference between TAVR and surgical aortic valve replacement. In patients with paradoxical LF and low gradient (preserved ejection fraction), TAVR reduced 1-year mortality from 66% to 35% (hazard ratio, 0.38; P=0.02). LF was an independent predictor of mortality in all patient cohorts (hazard ratio, ≈1.5), whereas ejection fraction and gradient were not. Conclusions-LF
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.