We report on the measurement of the γp → J/ψp cross section from Eγ = 11.8 GeV down to the threshold at 8.2 GeV using a tagged photon beam with the GlueX experiment. We find the total cross section falls toward the threshold less steeply than expected from two-gluon exchange models. The differential cross section dσ/dt has an exponential slope of 1.67 ± 0.39 GeV −2 at 10.7 GeV average energy. The LHCb pentaquark candidates P + c can be produced in the s-channel of this reaction. We see no evidence for them and set model-dependent upper limits on their branching fractions B(P + c → J/ψp).
We report measurements of the photon beam asymmetry Σ for the reactions γp → pπ 0 and γp → pη from the GLUEX experiment using a 9 GeV linearly-polarized, tagged photon beam incident on a liquid hydrogen target in Jefferson Lab's Hall D. The asymmetries, measured as a function of the proton momentum transfer, possess greater precision than previous π 0 measurements and are the first η measurements in this energy regime. The results are compared with theoretical predictions based on t-channel, quasi-particle exchange and constrain the axial-vector component of the neutral meson production mechanism in these models.
In recent years, there has been a debate on whether a considerable fraction of particles is retained after 24 h in the tracheobronchial region. In the present study, 8 healthy subjects inhaled 6.2-microns monodisperse Teflon particles labeled with 111 In twice, at flow rates of 0.45 and 0.045 L/s. According to theoretical calculations, the particles inhaled at 0.45 L/s should deposit mainly in large bronchi and in the alveolar region, whereas the particles inhaled at 0.045 L/s should be deposited mainly in small ciliated airways. Twenty-four hours after inhalation, about half of the particles inhaled with both modes of inhalation had cleared. Clearance during the period from 1 to about 30 days after inhalation, could, for both modes of inhalation, be described by the sum of two exponential functions. For the inhalation rate of 0.45 L/s, 15% cleared with a half-time of 3.4 days and 85% with a half-time of 190 days. For the inhalation of 0.045 L/s, 20% cleared with a half-time of 2.0 days and 80% with a half-time of 50 days. The results strongly indicate (1) that a considerable fraction of particles deposited in small ciliated airways had not cleared within 24 h, and (2) that these particles cleared differently from particles deposited in the alveolar region. The experimental data agree quite well with the IRTM predictions made using its default slow clearance fractions.
IMBA (Integrated Modules for Bioassay Analysis) is a suite of software modules that implement the current ICRP biokinetic and dosimetric models for estimation of intakes and doses. The IMBA modules have gone through extensive quality assurance, and are now used for routine formal dose assessment by Approved Dosimetry Services throughout the UK. HPA has continued to develop the IMBA modules. In addition, several projects, sponsored by organisations both in the USA and in Canada, have resulted in the development of customised user-friendly interfaces (IMBA Expert 'editions'). These enable users not only to use the standard ICRP models, but also to change many of the parameter values from ICRP defaults, and to apply sophisticated data handling techniques to internal dose calculations. These include: fitting measurement data with the maximum likelihood method; using multiple chronic and acute intakes; and dealing with different data types, such as urine, faces and whole body simultaneously. These interfaces were improved further as a result of user-feedback, and a general 'off-the-shelf' product, IMBA Professional, was developed and made available in January 2004. A new version, IMBA Professional Plus, was released in April 2005, which is both faster and more powerful than previous software. The aim of this paper is to describe the capabilities of IMBA Professional Plus, and the mathematical methods used.
The GlueX experiment at Je↵erson Lab has been designed to study photoproduction reactions with a 9-GeV linearly polarized photon beam. The energy and arrival time of beam photons are tagged using a scintillator hodoscope and a scintillating fiber array. The photon flux is determined using a pair spectrometer, while the linear polarization of the photon beam is determined using a polarimeter based on triplet photoproduction. Charged-particle tracks from interactions in the central target are analyzed in a solenoidal field using a central straw-tube drift chamber and six packages of planar chambers with cathode strips and drift wires. Electromagnetic showers are reconstructed in a cylindrical scintillating fiber calorimeter inside the magnet and a lead-glass array downstream. Charged particle identification is achieved by measuring energy loss in the wire chambers and using the flight time of particles between the target and detectors outside the magnet. The signals from all detectors are recorded with flash ADCs and/or pipeline TDCs into memories allowing trigger decisions with a latency of 3.3 µs. The detector operates routinely at trigger rates of 40 kHz and data rates of 600 megabytes per second. We describe the photon beam, the GlueX detector components, electronics, data-acquisition and monitoring systems, and the performance of the experiment during the first three years of operation.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.