Editor: S. DodelsonWe report a measurement of the flux of cosmic rays with unprecedented precision and statistics using the Pierre Auger Observatory. Based on fluorescence observations in coincidence with at least one surface detector we derive a spectrum for energies above 10 18 eV. We also update the previously published energy spectrum obtained with the surface detector array. The two spectra are combined addressing the systematic uncertainties and, in particular, the influence of the energy resolution on the spectral shape.
242Pierre Auger Collaboration / Physics Letters B 685 (2010) The spectrum can be described by a broken power law E −γ with index γ = 3.3 below the ankle which is measured at log 10 (E ankle /eV) = 18.6. Above the ankle the spectrum is described by a power law with index 2.6 followed by a flux suppression, above about log 10 (E/eV) = 19.5, detected with high statistical significance.
We describe the measurement of the depth of maximum, X{max}, of the longitudinal development of air showers induced by cosmic rays. Almost 4000 events above 10;{18} eV observed by the fluorescence detector of the Pierre Auger Observatory in coincidence with at least one surface detector station are selected for the analysis. The average shower maximum was found to evolve with energy at a rate of (106{-21}{+35}) g/cm{2}/decade below 10{18.24+/-0.05} eV, and (24+/-3) g/cm{2}/decade above this energy. The measured shower-to-shower fluctuations decrease from about 55 to 26 g/cm{2}. The interpretation of these results in terms of the cosmic ray mass composition is briefly discussed.
Severe fever with thrombocytopenia syndrome (SFTS), a tickborne viral disease, has been identified in China, South Korea, and Japan since 2009. We found retrospective evidence of SFTS virus (SFTSV) infection in Vietnam, which suggests that SFTSV infections also occur in Vietnam, where the virus has not been known to be endemic.
a b s t r a c tThe Pierre Auger Observatory is a hybrid detector for ultra-high energy cosmic rays. It combines a surface array to measure secondary particles at ground level together with a fluorescence detector to measure the development of air showers in the atmosphere above the array. The fluorescence detector comprises 24 large telescopes specialized for measuring the nitrogen fluorescence caused by charged particles of cosmic ray air showers. In this paper we describe the components of the fluorescence detector including its optical system, the design of the camera, the electronics, and the systems for relative and absolute calibration. We also discuss the operation and the monitoring of the detector. Finally, we evaluate the detector performance and precision of shower reconstructions.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.