Objective
To evaluate the experiences of families with very young children aged 1 to 7 years (inclusive) with type 1 diabetes using day‐and‐night hybrid closed‐loop insulin delivery.
Methods
Parents/caregivers of 20 children aged 1 to 7 years with type 1 diabetes completed a closed‐loop experience survey following two 3‐week periods of unrestricted day‐and‐night hybrid closed‐loop insulin therapy using Cambridge FlorenceM system at home. Benefits, limitations, and improvements of closed‐loop technology were explored.
Results
Responders reported reduced burden of diabetes management, less time spent managing diabetes, and improved quality of sleep with closed‐loop. Ninety percent of the responders felt less worried about their child's glucose control using closed‐loop. Size of study devices, battery performance and connectivity issues were identified as areas for improvement. Parents/caregivers wished for more options to input information to the system such as temporary glucose targets.
Conclusions
Parents/caregivers of very young children reported important quality of life benefits associated with using closed‐loop, supporting adoption of this technology in this population.
Aim
To evaluate the use of hybrid closed‐loop glucose control with faster‐acting insulin aspart (Fiasp) in adults with type 1 diabetes (T1D).
Research Design and Methods
In a double‐blind, multinational, randomized, crossover study, 25 adults with T1D using insulin pump therapy (mean ± SD, age 38 ± 9 years, HbA1c 7.4% ± 0.8% [57 ± 8 mmol/mol]) underwent two 8‐week periods of unrestricted living comparing hybrid closed‐loop with Fiasp and hybrid closed‐loop with standard insulin aspart in random order. During both interventions the CamAPS FX closed‐loop system incorporating the Cambridge model predictive control algorithm was used.
Results
In an intention‐to‐treat analysis, the proportion of time sensor glucose was in the target range (3.9–10.0 mmol/L; primary endpoint) was not different between interventions (75% ± 8% vs. 75% ± 8% for hybrid closed‐loop with Fiasp vs. hybrid closed‐loop with standard insulin aspart; mean‐adjusted difference −0.6% [95% CI −1.8% to 0.7%]; p < .001 for non‐inferiority [non‐inferiority margin 5%]). The proportion of time with sensor glucose less than 3.9 mmol/L (median [IQR] 2.4% [1.2%–3.2%] vs. 2.9% [1.7%–4.0%]; p = .01) and less than 3.0 mmol/L (median [IQR] 0.4% [0.2%–0.7%] vs. 0.7% [0.2%–0.9%]; p = .03) was reduced with Fiasp versus standard insulin aspart. There was no difference in mean glucose (8.1 ± 0.8 vs. 8.0 ± 0.8 mmol/L; p = .13) or glucose variability (SD of sensor glucose 2.9 ± 0.5 vs. 2.9 ± 0.5 mmol/L; p = .90). Total daily insulin requirements did not differ (49 ± 15 vs. 49 ± 15 units/day; p = .45). No severe hypoglycaemia or ketoacidosis occurred.
Conclusions
The use of Fiasp in the CamAPS FX closed‐loop system may reduce hypoglycaemia without compromising glucose control compared with standard insulin aspart in adults with T1D.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.