Use of the CF-RVSD for RVF is clinically feasible and associated with improved hemodynamic status. Observations from the registry of patients who have received this device may support the development of prospective studies that will examine the role of percutaneous circulatory support for RVF.
Blood flow restoration to ischemic tissue is affected by various risk factors. The aim of this study was to examine gender effects on arteriogenesis and angiogenesis in a mouse ischemic hindlimb model. C57BL/6J mice were subjected to unilateral hindlimb ischemia. Flow recovery was less and hindlimb use impairment was greater in females. No gender difference in vessel number was found at baseline, although 7 days postsurgery females had fewer α-smooth muscle actin-positive vessels in the midpoint of the adductor region. Females had higher hindlimb vascular resistance, were less responsive to vasodilators, and were more sensitive to vasoconstrictors postligation. Western blotting showed that females had higher baseline levels of vascular endothelial growth factor (VEGF) and endothelial nitric oxide synthase (eNOS) in the calf, while 7 days postligation males had higher levels of VEGF, eNOS, and phosphorylated vasodilator stimulated phosphoprotein. Females had less angiogenesis in a Matrigel plug assay and less endothelial cell proliferation in vitro. Females have impaired recovery of flow, a finding presumably caused by multiple factors including decreased collateral remodeling, less angiogenesis, impaired vasodilator response, and increased vasoconstrictor activity; our results also suggest the possibility that new collateral formation, from capillaries, is impaired in females.
Hemolysis is a potential limitation of percutaneously delivered left-sided mechanical circulatory support pumps, including trans valvular micro-axial flow pumps (TVP). Hemolytic biomarkers among durable left ventricular assist devices include lactate dehydrogenase (LDH) >2.5 times the upper limit of normal (ULN) and plasma-free hemoglobin (pf-Hb) >20 mg/dL. We examined the predictive value of these markers among patients with cardiogenic shock (CS) receiving a TVP. We retrospectively studied records of 116 consecutive patients receiving an Impella TVP at our institution between 2012 and 2017 for CS. Twenty-three met inclusion/exclusion criteria, and had sufficient pf-Hb data for analysis. Area under receiver-operator characteristic (ROC) curve for diagnosing hemolysis were calculated. Mean age was 62 ± 14 years and ejection fraction was 15 ± 5%. Mean duration of support was 5.4 ± 3.5 days. Pre-device LDH levels were >2.5x ULN in 71% (n = 5/7) of 5.0 and 29% of CP patients, while pre-device pf-Hb levels were >20 mg/dL in 14% (n = 1/7) of 5.0 and 25% (n = 4/16) of CP patients. Given elevated baseline LDH and pf-Hb levels, we defined hemolysis as a pf-Hb level >40 mg/dL within 72 h post-implant plus clinical evidence of device-related hemolysis. We identified that 30% (n = 7/23) had device-related hemolysis. Using ROC curve-derived cut-points, an increase in delta pf-Hb by >27mg/dL, not delta LDH, within 24 h after TVP implant (delta pf-Hb: C-statistic = 0.79, sensitivity: 57%, specificity: 93%, p <0.05) was highly predictive of hemolysis. In conclusion, we identified a change in pf-Hb, not LDH, levels is highly sensitive and specific for hemolysis in patients treated with a TVP for CS.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.