The aim of this study was to evaluate the left ventricular systolic and diastolic function before and after transcatheter percutaneous patent ductus arteriosus (PDA) closure. 21 children (age >6 months old) diagnosed with hemodynamically significant PDA underwent percutaneous PDA closure. Conventional, Doppler and tissue Doppler imaging and speckled-derived strain rate echocardiography were done at pre-closure, 1 day (early) and 1 month (late) post-closure. Mean age of the patients (female/male: 1.3) was 17.54 ± 24.7 months with the mean PDA diameter of 3.6 ± 0.8 mm. Systolic measures (ejection fraction, shortening fraction) reduced significantly early after PDA closure (P < 0.05). After 1 month, both improved significantly; ultimately, after 1 month no change was observed in systolic function measures compared with the pre-closure status. Early and late diastolic flow velocities of mitral (E M and A M) reduced considerably in early and late post-closure time (P < 0.05). Both early tissue Doppler early velocity of lateral mitral annulus (E'M) and early to late velocity ratio (E'M/A'M) of lateral mitral annulus decreased significantly (P = 0.02) in early post-closure. After 1 month, E'M increased considerably. (P = 0.01) but E'M/A'M had an insignificant rise (P > 0.05). E M/E'M ratio did not change in early post-closure but it had a considerable reduction in the subsequent month compared with the pre- and early post-closure (P < 0.001 for both occasions). Global and segmental longitudinal strain measures reduced significantly early after PDA closure (P < 0.05) but it improved remarkably in the subsequent month. Transcatheter PDA closure causes a significant decrease in left ventricular performance early after PDA closure which recovers completely within 1 month. Also PDA size can affect post-closure left ventricular function.
Background Transcatheter closure of intracardiac defects might be complicated by intravascular hemolysis. We evaluated hemolysis and its outcome after transcatheter closure of these defects. Methods and patients All patients who underwent transcatheter closure of patent ductus arteriosus, ventricular septal defect and atrial septal defect were included in this prospective study. Clinical data were obtained before and after the catheterization. Results One hundred and thirty-eight patients were enrolled; and four (3%) patients developed intravascular hemolysis; while two cases had residual shunt and two other cases had not residual flow. Although residual shunt occurred in ten patients, only 2 of these cases developed hemolysis. Patent ductus arteriosus closure was done for one of these cases and the other one, underwent perimembranous ventricular septal defect closure. Moreover, hemolysis occurred after device closure of patent ductus arteriosus in 2 of the other patients with no residual shunt. In this study the hemolysis was eliminated by conservative management within 2 weeks although residual shunt continued in this time. We observed a decline in lactate dehydrogenase value after catheterization in comparison with precatheterization, which was mainly among ventricular septal defect patients that might be due to mild chronic hemolysis in these patients. Conclusion Incidence of hemolysis after device closure was low, and occurred with and without residual flow and was eliminated by conservative management in 2 weeks, without the need for surgery, although the residual shunt was continued.
OBJECTIVES The prevention of pulmonary insufficiency (PI) is a crucial part of the tetralogy of Fallot repair. Many techniques have been introduced to construct valves from different materials for the right ventricular outflow tract, including the most commonly constructed monocusp valves. We are introducing a new bicuspid valve made intraoperatively using the autologous right atrial appendage (RAA) to prevent PI in these patients. METHODS The RAA valve was constructed and used in 21 patients with tetralogy of Fallot. The effective preservation of the native valve was impossible in all patients because of either a severe valve deformity or a small annulus. The RAA valve was created after ventricular septal defect closure and right ventricular outflow tract myectomy and was covered with a bovine transannular pericardial patch. The perioperative data were evaluated, and the echocardiography results were assessed immediately after operations and in follow-up with a median of 10.5 months. The data were retrospectively compared with 10 other patients with similar demographic data but with only transannular patches. RESULTS The mean age of the patients was 13.3 months. No mortality or related morbidity occurred after repair using the RAA valve. The PI severity early after the operation was trivial or no PI in 18 patients, and mild PI was observed in 3 patients, which progressed to moderate PI in one of them in the mean 12-month follow-up period. Fifteen patients had mild or no pulmonary stenosis, while moderate pulmonary stenosis was observed in 6 others. Compared with the other 10 patients with only transannular patches, the RAA valve patients had prolonged operative and clamping times, but no difference in postoperative course and shorter hospital stays. The degree of PI was, of course, significantly less in the RAA valve patients, but pulmonary stenosis was the same. CONCLUSIONS The RAA valve construction is a safe and effective technique to prevent PI after the tetralogy of Fallot repair, at least in terms of short- and mid-term results. A longer follow-up period is needed to confirm if this new valve can eliminate or significantly delay the need for pulmonary valve replacement in these patients.
Background Coronary artery fistula (CAF) is a rare congenital anomaly with a challenging scenario in children. This study reports our experience in transcatheter closure of CAF with Nit-Occlude PDA coil and midterm clinical and imaging follow-up. Methods Twelve children with congenital CAF between 2009 and 2019, mean age 2.05 ± 2.05 years (4 days to 7.2 years), mean weight 8.8 ± 4.83 (2.8–17 kg), who underwent transcatheter closure with PFM coil at the Namazi hospital, Shiraz, Iran, were reported. Echocardiography and electrocardiogram were done before and after the procedure (early, 3, and 6 months after), and Multi-slice computerized tomography or conventional coronary angiography was performed at least one year after closure. Results In a median follow-up of 5.5 years (range 13 months to 8 years), retrogradely closed fistula had no residual, and the fistula tract was wholly occluded, but in most anterogradely closed fistula, had a small residual, which made the fistula tract open and need additional coil closure. Conclusions Transcatheter closure of CAF with PFM coil is feasible and effective with low mortality and morbidity, although antegrade closure with this device may be accompanied by residual shunt and need for multiple coil insertion.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.