In recent years, several studies on large series of multiple myeloma (MM) patients have demonstrated the clinical utility of flow cytometry monitoring of minimal residual disease (flow-MRD) in bone marrow (BM), for improved assessment of response to therapy and prognostication. However, disturbing levels of variability exist regarding the specific protocols and antibody panels used in individual laboratories. Overall, consensus exists about the utility of combined assessment of CD38 and CD138 for the identification of BM plasma cells (PC); in contrast, more heterogeneous lists of markers are used to further distinguish between normal/reactive PCs and myeloma PCs in the MRD settings. Among the later markers, CD19, CD45, CD27, and CD81, together with CD56, CD117, CD200, and CD307, have emerged as particularly informative; however, no single marker provides enough specificity for clear discrimination between clonal PCs and normal PCs. Accordingly, multivariate analyses of single PCs from large series of normal/reactive vs. myeloma BM samples have shown that combined assessment of CD138 and CD38, together with CD45, CD19, CD56, CD27, CD81, and CD117 would be ideally suited for MRD monitoring in virtually every MM patient. However, the specific antibody clones, fluorochrome conjugates and sources of the individual markers determines its optimal (vs. suboptimal or poor) performance in an eight-color staining. Assessment of clonality, via additional cytoplasmic immunoglobulin (CyIg) j vs. CyIgk evaluation, may contribute to further establish the normal/reactive vs. clonal nature of small suspicious PC populations at high sensitivity levels, provided that enough cells are evaluated.