BACKGROUNDIn a previous trial involving patients with early autosomal dominant polycystic kidney disease (ADPKD; estimated creatinine clearance, ≥60 ml per minute), the vasopressin V 2 -receptor antagonist tolvaptan slowed the growth in total kidney volume and the decline in the estimated glomerular filtration rate (GFR) but also caused more elevations in aminotransferase and bilirubin levels. The efficacy and safety of tolvaptan in patients with later-stage ADPKD are unknown. METHODSWe conducted a phase 3, randomized withdrawal, multicenter, placebo-controlled, double-blind trial. After an 8-week prerandomization period that included sequential placebo and tolvaptan run-in phases, during which each patient's ability to take tolvaptan without dose-limiting side effects was assessed, 1370 patients with ADPKD who were either 18 to 55 years of age with an estimated GFR of 25 to 65 ml per minute per 1.73 m 2 of body-surface area or 56 to 65 years of age with an estimated GFR of 25 to 44 ml per minute per 1.73 m 2 were randomly assigned in a 1:1 ratio to receive tolvaptan or placebo for 12 months. The primary end point was the change in the estimated GFR from baseline to follow-up, with adjustment for the exact duration that each patient participated (interpolated to 1 year). Safety assessments were conducted monthly. RESULTSThe change from baseline in the estimated GFR was −2.34 ml per minute per 1.73 m 2 (95% confidence interval [CI], −2.81 to −1.87) in the tolvaptan group, as compared with −3.61 ml per minute per 1.73 m 2 (95% CI, −4.08 to −3.14) in the placebo group (difference, 1.27 ml per minute per 1.73 m 2 ; 95% CI, 0.86 to 1.68; P<0.001). Elevations in the alanine aminotransferase level (to >3 times the upper limit of the normal range) occurred in 38 of 681 patients (5.6%) in the tolvaptan group and in 8 of 685 (1.2%) in the placebo group. Elevations in the aminotransferase level were reversible after stopping tolvaptan. No elevations in the bilirubin level of more than twice the upper limit of the normal range were detected. CONCLUSIONSTolvaptan resulted in a slower decline than placebo in the estimated GFR over a 1-year period in patients with later-stage ADPKD. (Funded by Otsuka Pharmaceuticals and Otsuka Pharmaceutical Development and Commercialization; REPRISE ClinicalTrials.gov number, NCT02160145.)
Background: Citrasate®, citric acid dialysate (CD), contains 2.4 mEq of citric acid (citrate), instead of acetic acid (acetate) as in standard bicarbonate dialysate. Previous studies suggest CD may improve dialysis adequacy and decrease heparin requirements, presumably due to nonsystemic anticoagulant effects in the dialyzer. Methods: We prospectively evaluated 277 hemodialysis patients in eight outpatient facilities to determine if CD with reduced heparin N (HN) would maintain dialyzer clearance. Subjects progressed through four study periods [baseline (B): bicarbonate dialysate + 100% HN; period 1 (P1): CD + 100% HN; period 2 (P2): CD + 80% HN; period 3 (P3): CD + 66.7% HN]. The predefined primary endpoint was noninferiority (margin –8%) of the percent change in mean dialyzer conductivity clearance between baseline and P2. Results: Subjects were 57.4% male, 41.7% white, 54.3% black, and 44.4% diabetic; mean age was 59 ± 14.4 years; mean time on dialysis was 1,498 ± 1,165 days; 65.7% had arteriovenous fistula, 19.9% arteriovenous graft, 14.4% catheters, and 27.8% used antiplatelet agents. Mean dialyzer clearance increased 0.9% (P1), 1.0% (P2), and 0.9% (P3) with CD despite heparin reduction. SpKt/V remained stable (B: 1.54 ± 0.29; P1: 1.54 ± 0.28; P2: 1.55 ± 0.27; P3: 1.54 ± 0.26). There was no significant difference in dialyzer/dialysis line thrombosis, post-HD time to hemostasis, percent of subjects with adverse events (AEs), or study-related AEs. Conclusions: CD was safe, effective, and met all study endpoints. Dialyzer clearance increased approximately 1% with CD despite 20–33% heparin reduction. Over 92% of P3 subjects demonstrated noninferiority of dialyzer clearance with CD and 33% HN reduction. There was no significant difference in dialyzer clotting, bleeding, or adverse events.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.