We present the results of a study on the value of ultrasound in the detection of metastasis to the cervical lymph nodes in connection with cancer of the ear, nose, and throat. Comparison of clinical, ultrasound, and histological findings for 100 patients who underwent surgery revealed that clinical examination had a sensitivity of 78% versus 92.6% for ultrasound. All 18 cases of thrombosis of the internal jugular vein were detected by ultrasound. Clinical staging of the disease was modified in 28 of these patients based on ultrasound findings, including three false positive findings. Ultrasonographic follow-up at three months for a second group of 110 patients who did not undergo neck dissection provided prognostic information, since lesion stability or progression was correlated with death in less than one year in 41 of 43 patients. Ultrasound is of primary value in providing information of an anatomic nature, including the detection of subclinical lymph nodes, volumetric evaluation, and determination of vascular connections, particularly detection of internal jugular venous thrombosis. Furthermore, for patients whose necks have been thickened as a result of radiotherapy, ultrasound allows assessment of local status.
Use of the low-energy helium-neon laser (LEL) appears to be a simple atraumatic technique for the prevention and treatment of mucositis of various origins. Preliminary findings, and significant results obtained for chemotherapy-induced mucositis in a previous phase III study, prompted a randomized multicenter double-blind trial to evaluate LEL in the prevention of acute radiation-induced stomatitis. Irradiation by LEL corresponds to local application of a high-photon-density monochromatic light source. Activation of epithelial healing for LEL-treated surfaces, the most commonly recognized effect, has been confirmed by numerous in vitro studies. The mechanism of action at a molecular and enzymatic level is presently being studied. From September 1994 to March 1998, 30 patients were randomized. Technical specification: 60 mW (25 mW at Reims, 1 patient), He-Ne, wavelength 632.8 nm. The trial was open to patients with carcinoma of the oropharynx, hypopharynx and oral cavity, treated by radiotherapy alone (65 Gy at a rate of 2 Gy/fraction, 5 fractions per week) without prior surgery or concomitant chemotherapy. The malignant tumor had to be located outside the tested laser application areas (9 points): posterior third of the internal surfaces of the cheeks, soft palate and anterior tonsillar pillars. Patients were randomized to LEL or placebo light treatment, starting on the first day of radiotherapy and before each session. The treatment time (t) for each application point was given by the equation : t(s)= energy (J/cm2) x surface (cm2)/Power (W). Objective assessment of the degree of mucositis was recorded weekly by a physician blinded to the type of treatment, using the WHO scale for grading of mucositis and a segmented visual analogue scale for pain evaluation. Protocol feasibility and compliance were excellent. Grade 3 mucositis occured with a frequency of 35.2% without LEL and of 7.6% with LEL (P<0.01). The frequency of "severe pain" (grade 3) was 23.8% without LEL, falling to 1.9% with LEL (P<0.05). Pain relief was significantly reduced throughout the treatment period (weeks 2-7). LEL therapy is capable of reducing the severity and duration of oral mucositis associated with radiation therapy. In addition, there is a tremendous potential for using LEL in combined treatment protocols utilizing concomitant chemotherapy and radiotherapy.
From the theoretical point of view, the Faraday cup (FC) is an absolute instrument for fluence measurements of proton beams. As the FC is easily manufactured it can be considered an 'in-house' calibration system. Moreover, at the moment no national standards for proton dosimetry are available. Up to now the experimental tests of these instruments show that much study still has to be done to better understand their use in reference dosimetry. To investigate the possibility of using an FC as a secondary standard, an FC was jointly designed by the 'TERA Collaboration' and 'Centre Antoine-Lacassagne' (Nice, France) to evaluate the main parameters of the instrument. A comparison between two FCs of different designs--the 'TERA FC' and the 'Nice FC'--and an ionization chamber (IC) used for routine proton dosimetry was carried out. Results show that the two FCs agree to within 1.5-3.6%. While the differences between FC and IC are larger--6% for the 'TERA FC' and 8.2% for the 'Nice FC', the FC giving a lower dose evaluation--they follow the same trend shown by the calorimetric measurements. The data show that once the beam characteristics are defined, the fluence measurements are reproducible and show a good accuracy.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.