The management of split-thickness skin graft donor sites is targeted towards promoting the healing process, while minimizing adverse effects and complications. The aim of this study was to compare donor site treatment outcome between Aquacel, a carboxymethylcellulose-based hydrofiber dressing, and the standard mesh paraffin gauze dressing. The study included 23 adult patients. Half of the skin graft donor site in the proximal thigh was dressed with paraffin gauze and the rest with Aquacel. The results indicated that patients treated with Aquacel experienced significantly less pain and a more rapid rate of epithelialization compared with patients treated with mesh paraffin gauze dressing. Final scarring (ie, after the 1-year follow-up) was significantly better with the Aquacel dressing. We conclude that Aquacel dressing is superior to the standard mesh paraffin gauze dressing for split-thickness donor site area in pain relief, ease of treatment, promotion of epithelialization, and the quality of scarring.
Complex wounds that involve skin and soft-tissue defects that are unsuitable for primary closure by conventional suturing are common in the field of surgery. Among the many surgical options available to overcome these problems are various mechanical devices that have recently been proposed for delayed primary closure of such wounds. The authors present their experience with a new complex wound closure device, Wisebands, a device uniquely designed for skin and soft-tissue stretching. During the last 2 years, the authors have treated 20 patients with 22 skin and soft-tissue wounds for which primary closure was not feasible. The Wisebands devices were applied to the wounds, stretching the skin and underlying soft tissue, gradually closing the defects until the edges were sufficiently approximated for primary closure. Successful wound closure was achieved in 18 patients (90 percent). The Wisebands devices were removed in two patients (10 percent) because of major wound complications. In two other patients (10 percent), minor wound complications had occurred that did not necessitate removal of the device. At a mean follow-up of 1 year (range, 10 months to 2 years), stable scarring with no functional or significant aesthetic deficit was achieved. The authors conclude that the Wisebands device facilitates closure of complex skin and soft-tissue wounds, with low morbidity and complication rates, and can provide the surgeon with another important tool for closing complex wounds. Nevertheless, appropriate patient selection, intraoperative judgment, and close postoperative care are essential to ensure closure and avoid undue complications.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.