Postmortem studies suggest that coronary angiography does not always accurately delineate the extent of coronary-artery disease. We examined this problem in living human hearts by performing high-frequency epicardial echocardiography at the time of cardiac surgery. The ratio of the diameter of the lumen of the coronary artery to the thickness of its wall was used to quantify the severity of coronary lesions. In 11 patients with no angiographic evidence of coronary disease anywhere in the coronary tree, the mean (+/- SEM) ratio was 5.9 +/- 0.3. In 21 patients with angiographic disease at the site evaluated by echocardiography, the mean ratio was lower (2.3 +/- 0.2, P less than 0.05), reflecting encroachment into the arterial lumen by atherosclerotic plaque. In 15 patients with arterial segments that were angiographically normal but with arterial stenoses elsewhere in the coronary tree, the mean ratio was 4.1 +/- 0.3, with marked overlap with the values in the patients who had angiographic disease at the site of the echocardiographic evaluation. These results demonstrate, in living human hearts, that diffuse coronary atherosclerosis is often present when coronary angiography reveals only discrete stenoses. This finding suggests that coronary angiography may underestimate the severity and extent of coronary disease.
The efficacy of self-adhesive electrode pads for defibrillation and cardioversion was assessed in 80 patients who received 267 shocks from self-adhesive pads. In all but two patients, defibrillation or cardioversion was achieved at least once. The pads were equally effective when used in the apex-anterior or apex-posterior position. The transthoracic impedance using self-adhesive pads was 75 +/- 21 ohms (mean +/- standard deviation), which is similar to previously reported transthoracic impedance in defibrillation, using standard hand-held electrode paddles of 67 +/- 36 ohms. It is concluded that self-adhesive electrode pads are effective for defibrillation and cardioversion.
There is currently no accepted approach for intraoperative evaluation of the technical adequacy of coronary artery bypass graft anastomoses. High-frequency epicardial echocardiography performed intraoperatively could assess coronary artery bypass graft anastomoses by providing on-line short-axis (cross-sectional) and longitudinal two-dimensional images of the vessels. To validate measurements of anastomoses with high-frequency epicardial echocardiography, luminal diameter determined by high-frequency epicardial echocardiography was compared with that determined histologically after perfusion fixation in 12 dogs studied after coronary artery bypass grafting. Technical errors were deliberately created in some grafts. The results of these animal validation studies showed that maximum luminal diameter of the anastomosis by high-frequency epicardial echocardiography correlated well with histologic measurements (r = .92; high-frequency epicardial echocardiography = 0.8 histology + 0.3). All deliberately created technical errors were detected by an independent observer using high-frequency epicardial echocardiography. After completion of the animal studies, we demonstrated the clinical applicability of this approach in 12 patients. Fifteen coronary artery bypass graft anastomoses were examined intraoperatively with high-frequency epicardial echocardiography. The measured maximum luminal diameter of the anastomosis was greater than the maximum luminal diameter of the native artery, as expected, in all end-to-side anastomoses. However, the maximum luminal diameter of the side-to-side anastomoses was equal to or slightly less than that of the native artery. In this initial patient group, minor technical errors were noted in two of 15 graft anastomoses. In conclusion, high-frequency epicardial echocardiography can accurately measure coronary arterial bypass graft anastomoses and has potential for intraoperative detection of technical errors and inadequacies. Such information may provide a means to detect and correct these technical errors and inadequacies intraoperatively.
Sequential overlapping pulse shock waveforms facilitate defibrillation compared with single pulse shocks of the same total energy. This is due at least in part to the changing orientation of the electrical vector during the multiple pulse shock.
Our purpose was to assess the effect of myocardial ischemia, left ventricular hypertrophy, and systemic hypoxia and acid-base abnormalities on the energy requirements for defibrillation. We determined the defibrillation threshold (DFT), the minimum energy required to defibrillate. DFT was not significantly elevated after left anterior descending coronary occlusion, nor was there a relationship between the size of the occluded coronary distribution area (coronary risk area) and the change in DFT in individual animals. Renal hypertension and left ventricular hypertrophy were induced by unilateral nephrectomy and contralateral renal artery stenosis. DFT in left ventricular hypertrophy dogs was not significantly higher than in dogs without hypertrophy. Finally, we induced systemic hypoxia and acid-base abnormalities. Neither respiratory nor metabolic acid-base disturbances affected DFT, but during systemic hypoxia (O2 tension 45 +/- 2) DFT fell from 83 +/- 49 to 58 +/- 28 J (P less than 0.01). Thus in dogs, myocardial ischemia, left ventricular hypertrophy, and acid-base abnormalities do not elevate defibrillation energy requirements, whereas hypoxia reduces the energy needed to defibrillate.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.