Breast core needle biopsy (CNB) is used for sampling breast lesions in both the screening and diagnostic context. We present the accuracy of breast CNB from a consecutive series of 4035 core biopsies, using methods that minimise selection and verification bias. We calculate accuracy and underestimation of malignancy for both automated (14G) and directional vacuum-assisted (11G) CNB performed under stereotactic or sonographic guidance. Overall sensitivity of CNB is 94.2% (92.9-95.5%) and specificity is 88.1% (86.6-89.6%), positive and negative predictive values are 84.8% (82.9-86.7%) and 95.6% (94.6-96.6%), respectively. In sampling microcalcification, the overall underestimation of malignancy is 26.6% (22.9-30.3%): underestimation is significantly higher for automated CB relative to VAB (chi2 ((df = 1)) = 8.90 , P = 0.002), the absolute difference in underestimation being 14% (5-23%); sensitivity is higher for VAB than automated CB (chi2 ((df = 1)) = 3.28, P = 0.06) but specificity is significantly higher for automated CB (14G) relative to VAB (11G) (chi2 ((df = 1)) = 6.37, P = 0.01), and the overall accuracy of the two methods is similar. Sensitivity of CNB improved with experience (over time and in relation to caseload). Accuracy was not substantially affected by lesion palpability or image-guidance method, and was similar for both masses and calcification but lower for lesions depicted as distortions on mammography. Inadequacy was very low and decreased with greater operator caseload, and was not associated with core gauge or image-guidance method. False negatives occurred in 4.4% (3.4-5.4%) of cases, and where core histology was benign but discordant with (suspicious) imaging and/or clinical findings the likelihood of malignancy was 33.1% (18.5-47.7%), emphasising the importance of correlating all test information in breast diagnosis.
Second reading is effective in detecting a limited number of additional cancer cases. Tumour stage (one-third over 1 cm in diameter) and review findings (high rate of "screening errors" and BI-RADS R4b-c categories) suggest that second reading detects small "difficult cases" as well as larger cancers missed due to fatigue or loss of attention. Second reading reduces screening specificity to a minor extent, and since cancer detection at second reading seems cost-effective the procedure is recommendable in routine practice.
This study has analysed the generation of 3-(2-deoxy-β-D-erythro-pentafuranosyl) pyrimido [1,2-α] purin-10 (3H)-one deoxyguanosine adduct [M1dG], a biomarker of oxidative stress and lipid peroxidation, in breast fine-needle aspirate samples of 22 patients with breast cancer, at different clinical stages, in respect to 13 controls. The multivariate analysis show that M1dG adduct was higher in cases than in controls (Mean Ratio (MR) = 5.26, 95% CI = 3.16–8.77). Increased M1dG was observed in women with a tumour grade 3 and a pathological diameter 2 (MR = 7.61, 95% CI 3.91–14.80 and MR = 5.75, 95% CI = 3.13–10.59, respectively). A trend with increasing tumour grade and pathological diameter was present (MR = 1.98, 95% CI = 1.57–2.50 and MR = 2.44, 95% CI = 1.71–3.48, respectively). Not significant effects of age and smoking habit were found (MR = 1.58, 95% CI = 0.92–2.72 and MR = 1.68, 95% CI 0.88–3.20, respectively). An increment over the background frequency of M1dG can contribute to breast cancer development. Increasing severity of breast tumour can influence DNA damage level.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.