A kidney from a 56-year-old mother was transplanted to her 37-year-old daughter laparoscopically using the daVinci HDSi surgical system. The kidney was introduced into the abdomen through a 7-cm suprapubic incision used also for the uretero-vescical anastomosis. Vascular anastomoses were carried out through a total of three additional ports. Surgery lasted 154 min, including 51 min of warm ischemia of the graft. Urine production started immediately after graft reperfusion. Renal function remains optimal at the longest follow-up of 3 months. The technique employed in this case is discussed in comparison with the only other two contemporary experiences, both from the USA. Furthermore, possible advantages and disadvantages of robotics in kidney transplantation are discussed extensively. We conclude that the daVinci surgical system allows the performance of kidney transplantation under optimal operative conditions. Further experience is needed, but it is likely that solid organ transplantation will not remain immune to robotics
AIMTo investigate the role of minimally invasive surgery for gastric cancer and determine surgical, clinical, and oncological outcomes.METHODSThis is a propensity score-matched case-control study, comparing three treatment arms: robotic gastrectomy (RG), laparoscopic gastrectomy (LG), open gastrectomy (OG). Data collection started after sharing a specific study protocol. Data were recorded through a tailored and protected web-based system. Primary outcomes: harvested lymph nodes, estimated blood loss, hospital stay, complications rate. Among the secondary outcomes, there are: operative time, R0 resections, POD of mobilization, POD of starting liquid diet and soft solid diet. The analysis includes the evaluation of type and grade of postoperative complications. Detailed information of anastomotic leakages is also provided.RESULTSThe present analysis was carried out of 1026 gastrectomies. To guarantee homogenous distribution of cases, patients in the RG, LG and OG groups were 1:1:2 matched using a propensity score analysis with a caliper = 0.2. The successful matching resulted in a total sample of 604 patients (RG = 151; LG = 151; OG = 302). The three groups showed no differences in all baseline patients characteristics, type of surgery (P = 0.42) and stage of the disease (P = 0.16). Intraoperative blood loss was significantly lower in the LG (95.93 ± 119.22) and RG (117.91 ± 68.11) groups compared to the OG (127.26 ± 79.50, P = 0.002). The mean number of retrieved lymph nodes was similar between the RG (27.78 ± 11.45), LG (24.58 ± 13.56) and OG (25.82 ± 12.07) approach. A benefit in favor of the minimally invasive approaches was found in the length of hospital stay (P < 0.0001). A similar complications rate was found (P = 0.13). The leakage rate was not different (P = 0.78) between groups.CONCLUSIONLaparoscopic and robotic surgery can be safely performed and proposed as possible alternative to open surgery. The main highlighted benefit is a faster postoperative functional recovery.
We have shown the feasibility of laparoscopic robot-assisted solitary pancreas and simultaneous pancreas and kidney transplantation. If the safety and feasibility of this procedure can be confirmed by larger series, laparoscopic robot-assisted pancreas transplantation could become a new option for diabetic patients needing beta-cell replacement.
Primary endo-GIA stapler malfunction occurred during robotic wedge resection of liver segments VII and VIII en-bloc with the right hepatic vein, in an obese woman diagnosed with single liver metastasis from a previous carcinoid tumour. Haemorrhage was soon controlled by clamping the vena cava below the injury using two wristed forceps angled at 90 degrees . With the two instruments locked in the holding position the ensuing operative strategy was discussed between surgeon and anaesthesia teams. Using the third robotic arm the caval injury was repaired laparoscopically with interrupted polypropylene sutures. The patient was transfused with two units of packed red blood cells, recovered uneventfully, and was discharged on post-operative day five. We conclude that even the most advanced technologies can fail and that surgeons should be fully aware of the consequences of these malfunctions and be prepared for repair. From this point of view, the da Vinci surgical system seems to have some advantages over classical laparoscopic methods including the ability to lock the wristed instruments in the holding position, the use of three arms by the same operating surgeon, and the extreme facilitation of intracorporeal suturing and knot-tying in deep and narrow spaces, extremely difficult if not impossible with conventional laparoscopic instruments.
Duodenal graft complications (DGC) occur frequently after pancreas transplantation but rarely cause graft loss. Graft pancreatectomy, however, may be required when DGC compromise recipient's safety. We herein report on two patients with otherwise untreatable DGC in whom the entire pancreas was salvaged by means of total duodenectomy with enteric drainage of both pancreatic ducts. The first patient developed recurrent episodes of enteric bleeding, requiring hospitalization and blood transfusions, starting 21 months after transplantation. The disease causing hemorrhage could not be defined, despite extensive investigations, but the donor duodenum was eventually identified as the site of bleeding. The second patient was referred to us with a duodenal stump leak, 5 months after transplantation. Two previous surgeries had failed to seal the leak, despite opening a diverting stoma above the duodenal graft. Thirty-nine and 16 months after total duodenectomy with dual duct drainage, respectively, both patients are insulin-independent and free from abdominal complaints. Magnetic resonance pancreatography shows normal ducts both basal and after intravenous injection of secretin. The two cases presented herein show that when DGC jeopardize pancreas function or recipient safety, total duodenectomy with enteric duct drainage may become an option.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.