NIV is a useful respiratory support technique in paediatric patients. Type 1 group classification, higher PRISM score, and lower RR decrease during NIV were independent risk factors for NIV failure.
BackgroundNon-invasive ventilation (NIV) may be useful after extubation in children. Our objective was to determine postextubation NIV characteristics and to identify risk factors of postextubation NIV failure.MethodsA prospective observational study was conducted in an 8-bed pediatric intensive care unit (PICU). Following PICU protocol, NIV was applied to patients who had been mechanically ventilated for over 12 hours considered at high-risk of extubation failure -elective NIV (eNIV), immediately after extubation- or those who developed respiratory failure within 48 hours after extubation -rescue NIV (rNIV)-. Patients were categorized in subgroups according to their main underlying conditions. NIV was deemed successful when reintubation was avoided. Logistic regression analysis was performed in order to identify predictors of NIV failure.ResultsThere were 41 episodes (rNIV in 20 episodes). Success rate was 50% in rNIV and 81% in eNIV (p = 0.037). We found significant differences in univariate analysis between success and failure groups in respiratory rate (RR) decrease at 6 hours, FiO2 at 1 hour and PO2/FiO2 ratio at 6 hours. Neurologic condition was found to be associated with NIV failure. Multiple logistic regression analysis identified no variable as independent NIV outcome predictor.ConclusionsOur data suggest that postextubation NIV seems to be useful in avoiding reintubation in high-risk children when applied immediately after extubation. NIV was more likely to fail when ARF has already developed (rNIV), when RR at 6 hours did not decrease and if oxygen requirements increased. Neurologic patients seem to be at higher risk of reintubation despite NIV use.
EMC of CVC were common in a teaching university hospital, but severe complications were very uncommon. Resident failure to perform CVC, high venous access, and number of attempts were independent risk factors for EMC of CVC.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.