We present a theory of thermal laser ablation based on the heat equation and on an energy balance equation derived from it. Ablation is assumed to be brought about by the heating and evaporation of tissue water. The model is three-dimensional, and scattering and the water-steam phase transition are explicitly taken into account. The model predicts threshold parameters and a steady-state ablation velocity in terms of the optical and thermal properties of the tissue and the laser beam intensity and spot diameter.
The use of miniaturized pressure and velocity sensors mounted on angioplasty guidewires allows the simultaneous measurement of coronary blood flow velocity and transstenotic pressure gradient, 2 parameters that, combined, should perfectly characterize stenosis hemodynamics. The aim of this article is assessment of the changes in coronary blood flow velocity observed with a Doppler-tipped angioplasty guidewire in 35 patients undergoing balloon angioplasty. We also report our initial experience in 16 patients with the combined use of sensor-tip pressure and Doppler guidewires, and we discuss the application of new methodologic approaches for the study of the coronary circulation allowed by these techniques, such as the instantaneous assessment of the flow velocity/pressure and pressure gradient/flow velocity relations. Before and after angioplasty, flow velocity measurements were obtained distal to the stenosis, both in baseline conditions and after intracoronary injection of 8-12.5 mg of papaverine. The Doppler guidewire was left in place during the dilation procedure and the Doppler signal was continuously recorded during balloon inflation and after deflation to monitor the development of collateral flow, the restoration of flow after balloon deflation, the phase of postocclusive reactive hyperemia, and, incidently, the development of flow-limiting complications. Merits and pitfalls of several flow velocity parameters (average peak velocity, coronary flow velocity reserve, diastolic/systolic velocity ratio), as well as of parameters derived from the combination of pressure and velocity measurements (transstenotic pressure gradient/flow velocity relation and instantaneous diastolic hyperemic flow velocity/pressure relation) were evaluated in 35 patients with, and 37 without, significant coronary stenoses.(ABSTRACT TRUNCATED AT 250 WORDS)
In matched groups of patients, atherectomy induces a greater initial gain in minimal lumen diameter than does balloon angioplasty. However, the vascular wall injury induced by the device is of a different nature (debulking vs. dilating) that leads to more relative loss over the follow-up period in the atherectomy group.
Excimer laser angioplasty followed by balloon angioplasty provides no benefit additional to balloon angioplasty alone with respect to the initial and long-term clinical and angiographic outcome in the treatment of obstructive coronary artery disease.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.