Background: Elderly patients with a displaced femoral neck fracture treated with hip arthroplasty may have better function than those treated with internal fixation. We hypothesized that hemiarthroplasty would be superior to screw fixation with regard to hip function, mobility, pain, quality of life, and the risk of a reoperation in elderly patients with a nondisplaced femoral neck fracture. Methods: In a multicenter randomized controlled trial (RCT), Norwegian patients ≥70 years of age with a nondisplaced (valgus impacted or truly nondisplaced) femoral neck fracture were allocated to screw fixation or hemiarthroplasty. Assessors blinded to the type of treatment evaluated hip function with the Harris hip score (HHS) as the primary outcome as well as on the basis of mobility assessed with the timed “Up & Go” (TUG) test, pain as assessed on a numerical rating scale, and quality of life as assessed with the EuroQol-5 Dimension-3 Level (EQ-5D) at 3, 12, and 24 months postsurgery. Results, including reoperations, were assessed with intention-to-treat analysis. Results: Between February 6, 2012, and February 6, 2015, 111 patients were allocated to screw fixation and 108, to hemiarthroplasty. At the time of follow-up, there was no significant difference in hip function between the screw fixation and hemiarthroplasty groups, with a 24-month HHS (and standard deviation) of 74 ± 19 and 76 ± 17, respectively, and an adjusted mean difference of −2 (95% confidence interval [CI] = −6 to 3; p = 0.499). Patients allocated to hemiarthroplasty were more mobile than those allocated to screw fixation (24-month TUG = 16.6 ± 9.5 versus 20.4 ± 12.8 seconds; adjusted mean difference = 6.2 seconds [95% CI = 1.9 to 10.5 seconds]; p = 0.004). Furthermore, screw fixation was a risk factor for a major reoperation, which was performed in 20% (22) of 110 patients who underwent screw fixation versus 5% (5) of 108 who underwent hemiarthroplasty (relative risk reduction [RRR] = 3.3 [95% CI = 0.7 to 10.0]; number needed to harm [NNH] = 6.5; p = 0.002). The 24-month mortality rate was 36% (40 of 111) for patients allocated to internal fixation and 26% (28 of 108) for those allocated to hemiarthroplasty (RRR = 0.4 [95% CI = −0.1 to 1.1]; p = 0.11). Two patients were lost to follow-up. Conclusions: In this multicenter RCT, hemiarthroplasty was not found to be superior to screw fixation in reestablishing hip function as measured by the HHS (the primary outcome). However, hemiarthroplasty led to improved mobility and fewer major reoperations. The findings suggest that certain elderly patients with a nondisplaced femoral neck fracture may benefit from being treated with a latest-generation hemiarthroplasty rather than screw fixation. Level of Evidence: Therapeutic Level I. See Instructions for Authors for a complete description of levels of evidence.
Background and purposeIt has been suggested that preoperative posterior tilt of the femoral head may increase the risk of fixation failure in Garden-I and -II femoral neck fractures. To investigate this association, we studied a cohort of 322 such patients.Patients and methodsPatients treated with internal fixation between 2005 and 2012 were retrospectively identified using hospital records and the digital image bank. 2 raters measured the preoperative posterior tilt angle and categorized it into 3 groups: < 10°, 10–20°, and ≥ 20°. The inter-rater reliability (IRR) was determined. Patients were observed until September 2013 (with a minimum follow-up of 18 months) or until failure of fixation necessitating salvage arthroplasty. The risk of fixation failure was assessed using competing-risk regression analysis, adjusting for time to surgery.ResultsPatients with a posterior tilt of ≥ 20° had a higher risk of fixation failure: 19% (8/43) as compared to 11% (14/127) in the 10–20° category and 6% (9/152) in the < 10° category (p = 0.03). Posterior tilt of ≥ 20° increased the risk of fixation failure, with an adjusted hazard ratio of 3.4 (95% CI: 1.3–8.9; p = 0.01). The interclass correlation coefficient for angular measurements of posterior tilt was 0.90 (95% CI: 0.87–0.92), and the IRR for the categorization of posterior tilt into 3 groups was 0.76 (95% CI: 0.69–0.81).InterpretationPreoperative posterior tilt of ≥ 20° in Garden-I and -II femoral neck fractures increased the risk of fixation failure necessitating salvage arthroplasty. The reliability of the methods that we used to measure posterior tilt ranged from good to excellent.
BackgroundSeveral patient reported outcome measures (PROMs) are available for assessing the outcomes of ankle fracture but few have been compared for recommended measurement properties. This study compares the measurement properties of the Lower Extremity Function Scale (LEFS), Olerud Molander Ankle Score (OMAS) and Self-Reported Foot and Ankle Score (SEFAS) following ankle surgery.MethodsThe retrospective cohort study included 959 patients aged 18 years and over who underwent surgical treatment (ORIF) for unstable and closed ankle fractures in SE Norway. The PROMs were included in a postal questionnaire sent to patients’ homes in 2015, three years after surgery. Missing data, structural validity, internal consistency, test-retest reliability and validity were assessed.ResultsConfirmatory factor analysis results showed model fit for the SEFAS and a bi-dimensional LEFS with scales of easy and difficult items. The OMAS performed less satisfactorily. Cronbach’s alpha and test-retest correlations ranged from 0.82 to 0.96 and 0.91 to 0.93 respectively. The smallest detectable differences for group and individual comparisons were 14.1 to 20.6 and 0.93 to 1.55; SEFAS performed best. As hypothesised, instrument scores were highly correlated and with those for the EQ-5D and SF-36 physical functioning. Mean imputation where half or more items are completed increased usable scores by 1.4–15.7% without affecting measurement properties.ConclusionsThe three instruments largely performed satisfactorily in relation to important measurement properties but the LEFS had evidence for two dimensions relating to easier and more difficult aspects of function. Mean imputation where half or more items are completed increased the number of usable responses for all three instruments. The three instruments represent different approaches to measuring outcomes and their content should be considered carefully when choosing between them. The SEFAS is designed for a range of foot disorders including ankle fractures and has the best measurement properties in this population.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.