The purpose of this study was to examine the prognosis for patients with head and neck cancer after reirradiation using Cyberknife stereotactic body irradiation with special focus on mucosal ulceration. We conducted a retrospective multi-institutional review of 107 patients with previously irradiated head and neck cancer. The median follow-up time for all patients was 15 months, and the 2-year overall survival rate was 35%. Significant prognostic factors for overall survival were primary site (nasopharynx versus other sites), presence of ulceration, and PTV volume. Detailed analysis of ulceration showed a lower response rate (28%) in the ulceration (+) group than the ulceration (−) group (63%; P = 0.0045). The 2-year overall survival rates were 8% in the ulceration (+) group and 42.7% (P = 0.0001) in the ulceration (−) group, respectively. We recorded 22 severe toxicities, including 11 patients with carotid blow-out syndrome (CBOS), which was fatal in 9 patients. CBOS occurred in 6 patients with ulceration (6/25; 24%), and 5 patients experienced CBOS without ulceration (5/82; 6%; P=0.027). In conclusion, ulceration is an important prognostic factor, not only for adverse events but also for survival after reirradiation using CyberKnife.
BackgroundTo assess inter-observer variability in delineating target volume and organs at risk in benign tumor adjacent to optic tract as a quality assurance exercise.MethodsWe quantitatively analyzed 21 plans made by 11 clinicians in seven CyberKnife centers. The clinicians were provided with a raw data set (pituitary adenoma and meningioma) including clinical information, and were asked to delineate the lesions and create a treatment plan. Their contouring and plans (10 adenoma and 11 meningioma plans), were then compared. In addition, we estimated the influence of differences in contouring by superimposing the respective contours onto a default plan.ResultsThe median planning target volume (PTV) and the ratio of the largest to the smallest contoured volume were 9.22 cm3 (range, 7.17 - 14.3 cm3) and 1.99 for pituitary adenoma, and 6.86 cm3 (range 6.05 - 14.6 cm3) and 2.41 for meningioma. PTV volume was 10.1 ± 1.74 cm3 for group 1 with a margin of 1 -2 mm around the CTV (n = 3) and 9.28 ± 1.8 cm3(p = 0.51) for group 2 with no margin (n = 7) in pituitary adenoma. In meningioma, group 1 showed larger PTV volume (10.1 ± 3.26 cm3) than group 2 (6.91 ± 0.7 cm3, p = 0.03). All submitted plan keep the irradiated dose to optic tract within the range of 50 Gy (equivalent total doses in 2 Gy fractionation). However, contours superimposed onto the dose distribution of the default plan indicated that an excessive dose 23.64 Gy (up to 268% of the default plan) in pituitary adenoma and 24.84 Gy (131% of the default plan) in meningioma to the optic nerve in the contours from different contouring.ConclusionQuality assurance revealed inter-observer variability in contour delineation and their influences on planning for pituitary adenoma and meningioma near optic tract.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.