Abstract:The asymmetric influence of the volute on the flow in a transonic, high-pressure ratio centrifugal compressor at off-design conditions was investigated. Fully three-dimensional viscous steady-state computational fluid dynamics (CFD) was applied to simulate the flow in a 4.2:1 design pressure ratio compressor for automotive application. Computed performance characteristics are presented for low-and high-pressure ratio operating conditions, with and without an overhung volute. The volute was found to severely harm aerodynamic stability of the investigated compressor when operating at lower than design mass flow. The relative narrowing effect of the volute on compressor map width increases with pressure ratio up to a 42 per cent drop in stable flow range at design speed. The inter-passage variations in performance quantities and the influence of the volute tongue region are discussed in detail. The circumferential variations of incidence angle correlate with rotational speed, which, in combination with the higher sensitivity to incidence angle at transonic inflow conditions, seems to deteriorates stability when transonic inflow conditions are reached.
This is Part I of a two-part paper documenting the development of a novel asymmetric flow control method to improve the stability of a high-pressure-ratio turbocharger centrifugal compressor. Part I focuses on the nonaxisymmetrical flow in a centrifugal compressor induced by the nonaxisymmetrical geometry of the volute while Part II describes the development of an asymmetric flow control method to avoid the stall on the basis of the characteristic of nonaxisymmetrical flow. To understand the asymmetries, experimental measurements and corresponding numerical simulation were carried out. The static pressure was measured by probes at different circumferential and stream-wise positions to gain insights about the asymmetries. The experimental results show that there is an evident nonaxisymmetrical flow pattern throughout the compressor due to the asymmetric geometry of the overhung volute. The static pressure field in the diffuser is distorted at approximately 90 deg in the rotational direction of the volute tongue throughout the diffuser. The magnitude of this distortion slightly varies with the rotational speed. The magnitude of the static pressure distortion in the impeller is a function of the rotational speed. There is a significant phase shift between the static pressure distributions at the leading edge of the splitter blades and the impeller outlet. The numerical steady state simulation neglects the aforementioned unsteady effects found in the experiments and cannot predict the phase shift, however, a detailed asymmetric flow field structure is obviously obtained.
This is part II of a two-part paper involving the development of an asymmetrical flow control method to widen the operating range of a turbocharger centrifugal compressor with high-pressure ratio. A nonaxisymmetrical self-recirculation casing treatment (SRCT) as an instance of asymmetrical flow control method is presented. Experimental and numerical methods were used to investigate the impact of nonaxisymmetrical SRCT on the surge point of the centrifugal compressor. First, the influence of the geometry of a symmetric SRCT on the compressor performance was studied by means of numerical simulation. The key parameter of the SRCT was found to be the distance from the main blade leading edge to the rear groove (S). Next, several arrangements of a nonaxisymmetrical SRCT were designed, based on flow analysis presented in part I. Then, a series of experiments were carried out to analyze the influence of nonaxisymmetrical SRCT on the compressor performance. Results show that the nonaxisymmetrical SRCT has a certain influence on the performance and has a larger potential for stability improvement than the traditional symmetric SRCT. For the investigated SRCT, the surge flow rate of the compressor with the nonaxisymmetrical SRCTs is about 10% lower than that of the compressor with symmetric SRCT. The largest surge margin (smallest surge flow rate) can be obtained when the phase of the largest S is coincident with the phase of the minimum static pressure in the vicinity of the leading edge of the splitter blades.
This is the Part I of a two-part paper documenting the development of a novel asymmetric flow control method to improve the stability of a high-pressure-ratio turbocharger centrifugal compressor. Part I focuses on the non-axisymmetric flow in a centrifugal compressor induced by the non-axisymmetric geometry of the volute while Part II describes the development of asymmetric flow control method to avoid the stall on the basis of the characteristic of non-axisymmetric flow. To understand the asymmetries, experimental measurements and corresponding numerical simulation were carried out. The static pressure was measured by probes at different circumferential and stream-wise positions to gain insights about the asymmetries. The experiment results show that there is an evident non-axisymmetric flow pattern throughout the compressor due to the asymmetric geometry of overhung volute. The static pressure field in the diffuser is distorted at approximately 90° in rotational direction of the volute tongue throughout the diffuser. The magnitude of this distortion varies slightly with the rotational speeds. The magnitude of the static pressure distortion in the impeller is a function of the rotational speed. There is a significant phase shift between the static pressure distributions at the leading edge of the splitter blades and the impeller outlet. The numerical steady state simulation neglects the mentioned unsteady effects found in the experiments and can not predict the phase shift, but a detailed asymmetric flow field structure are obviously obtained.
This is the Part II of a two-part paper involving the development of asymmetric flow control method to widen the operating range of a turbocharger centrifugal compressor with high-pressure-ratio. Non-axisymmetric Self Recirculation Casing Treatment (SRCT) as an instance of asymmetric flow control method is presented. Experimental and numerical methods were used to investigate the impact of non-axisymmetric SRCT on surge point of the centrifugal compressor. Firstly, the influence of the geometry of a symmetric SRCT on the compressor performance was studied by means of numerical simulation. The key parameter of the SRCT was found to be the distance from the main blade leading edge to the rear groove (Sr). Next, several arrangements of a non-axisymmetric SRCT were designed, based on flow analysis presented in Part I. Then, a series of experiments was carried out to analyze the influence of non-axisymmetric SRCT on the compressor performance. Results show that the non-axisymmetry SRCT has certain influence on performance and has a larger potential for stability improvement than the traditional symmetric SRCT. For the investigated SRCT, the surge flow rate of the compressor with the non-axisymmetric SRCT is about 10% lower than that of the compressor with symmetric SRCT. The largest surge margin (smallest surge flow rate) can be obtained when the phase of the largest Sr is coincident with the phase of the minimum static pressure in the vicinity of the leading edge of the splitter blades.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.