Proton resonance frequency shift (PRFS) MR thermometry (MRT) is the generally preferred method for monitoring thermal ablation, typically implemented with gradient-echo (GRE) sequences. Standard PRFS MRT is based on the subtraction of a temporal reference phase map and is, therefore, intrinsically sensitive to tissue motion (including deformation) and to external perturbation of the magnetic field. Reference-free (or reference-less) PRFS MRT has been previously described by Rieke and was based on a 2-D polynomial fit performed on phase data from outside the heated region, to estimate the background phase inside the region of interest. While their approach was undeniably a fundamental progress in terms of robustness against tissue motion and magnetic perturbations, the underlying mathematical formalism requires a thick unheated border and may be subject to numerical instabilities with high order polynomials. A novel method of reference-free PRFS MRT is described here, using a physically consistent formalism, which exploits mathematical properties of the magnetic field in a homogeneous or near-homogeneous medium. The present implementation requires as input the MR GRE phase values along a thin, nearly-closed and unheated border. This is a 2-D restriction of a classic Dirichlet problem, working on a slice per slice basis. The method has been validated experimentally by comparison with the “ground truth” data, considered to be the standard PRFS method for static ex vivo tissue. “Zero measurement” of the gradient-echo phase baseline was performed in healthy volunteer liver with rapid acquisition (300 ms/image). In vivo data acquired in sheep liver during MR-guided high intensity focused ultrasound (MRgHIFU) sonication were post-processed as proof of applicability in a therapeutic scenario. Bland and Altman mean absolute difference between the novel method and the “ground truth” thermometry in ex vivo static tissue ranged between 0.069 °C and 0.968 °C, compared to the inherent “white” noise SD of 0.23 °C. The accuracy and precision of the novel method in volunteer liver were found to be on average 0.13 °C and respectively 0.65 °C while the inherent “white” noise SD was on average 0.51 °C. The method was successfully applied to large ROIs, up to 6.2 cm inner diameter, and the computing time per slice was systematically less than 100 ms using C++. The current limitations of reference-free PRFS thermometry originate mainly from the need to provide a nearly-closed border, where the MR phase is artifact-free and the tissue is unheated, plus the potential need to reposition that border during breathing to track the motion of the anatomic zone being monitored.A reference-free PRFS thermometry method based on the theoretical framework of harmonic functions is described and evaluated here. The computing time is compatible with online monitoring during local thermotherapy. The current reference-free MRT approach expands the workflow flexibility, eliminates the need for respiratory triggers, enables higher temporal resolution, an...
MR acoustic radiation force imaging (ARFI) is an elegant adjunct to MR-guided high intensity focused ultrasound for treatment planning and optimization, permitting in situ assessment of the focusing and targeting quality. The thermal effect of high intensity focused ultrasound pulses associated with ARFI measurements is recommended to be monitored on line, in particular when the beam crosses highly absorbent structures or interfaces (e.g., bones or air-filled cavities). A dedicated MR sequence is proposed here, derived from a segmented gradient echo-echo planar imaging kernel by adding a bipolar motion encoding gradient with interleaved alternating polarities. Temporal resolution was reduced to 2.1 s, with in-plane spatial resolution of 1 mm. MR-ARFI measurements were executed during controlled animal breathing, with trans-costal successively steered foci, to investigate the spatial modulation of the focus intensity and the targeting offset. ARFI-induced tissue displacement measurements enabled the accurate localization, in vivo, of the high intensity focused ultrasound focal point in sheep liver, with simultaneous monitoring of the temperature elevation. ARFI-based precalibration of the focal point position was immediately followed by trans-costal MR-guided high intensity focused ultrasound ablation, monitored with a conventional proton resonance frequency shift MR thermometry sequence. The latter MR thermometry sequence had spatial resolution and geometrical distortion identical with the ARFI maps, hence no coregistration was required. Magn Reson Med 68:932-946,
Magnetic resonance imaging (MRI) and ultrasonography have been used simultaneously in this ex vivo study for the image-guidance of high intensity focused ultrasound (HIFU) treatment in moving tissue. A ventilator-driven balloon produced periodic and non-rigid (i.e. breathing-like) motion patterns in phantoms. MR-compatible ultrasound (US) imaging enabled near real-time 2D motion tracking based on optical flow detection, while near-harmonic reference-free proton resonance frequency shift (PRFS) MR thermometry (MRT) was used to monitor the thermal buildup on line. Reference-free MRT was applied to gradient-echo echo-planar imaging phase maps acquired at the frame rate of 250 to 300 ms/slice with voxel size 1.25×1.25×5 mm(3). The MR-US simultaneous imaging was completely free of mutual interferences while minor RF interferences from the HIFU device were detected in the far field of the US images. The effective duty-cycle of the HIFU sonication was close to 100 % and no off-interval was required to temporally decouple it from the ultrasonography. The motion compensation of the HIFU sonication was achieved with an 8 Hz frame rate and sub-millimeter spatial accuracy, both for single-focus mode and for an iterated multi-foci line scan. Near harmonic reference-less PRFS MRT delivered motion-robust thermal maps perpendicular or parallel to the HIFU beam (0.7 °C precision, 0.5 °C absolute accuracy). Out-of-plane motion compensation was not addressed in this study.
A readily available, MR-compatible, effective, and cost-competitive method for rib protection in transcostal MRgHIFU was validated in this study, using specific reflective strips. The current approach permitted safe intercostal ablation of small volumes (0.7 mL) of liver parenchyma.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2025 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.