A whole-body MSCT-based diagnostic approach to multiple injuries might shorten the time interval from arrival in the trauma emergency room until obtaining a final diagnosis and management plan in patients with multiple injuries and might, therefore, contribute to improvements in patient care.
The prevalence of chronic kidney disease (CKD) is high in patients with atrial fibrillation (AF). Left atrial appendage closure (LAAC) has been recognized as an efficient alternative to oral anticoagulation for the prevention of thromboembolic events in patients with non-valvular AF (NVAF); however, the long-term safety and efficacy of LAAC in patients with CKD remain unclear. This study was designed to provide data regarding the safety and efficacy of LAAC in NVAF patients with CKD. A real-world analysis of the safety and efficacy of LAAC was performed on a cohort of 300 NVAF patients with or without CKD who underwent LAAC using the Watchman (WM) device at our center. The patients with CKD (n = 151) were significantly older (77.0 ± 7.2 vs. 73.2 ± 7.8 years, respectively, P < 0.0001) and had a higher CHA2DS2-VASc score (4.3 ± 1.5 vs. 3.4 ± 1.4, respectively, P < 0.0001) and HAS-BLED score (4.0 ± 1.0 vs. 3.0 ± 1.0, respectively, P < 0.0001) than the patients without CKD (n = 149). However, there were no differences between groups with respect to the device implant success rate (98.7 vs. 97.3%, respectively, P = 0.446) or severe periprocedural complications within 7 days. The patients were followed up for 637 ± 398 days, and all patients received repeat transesophageal echocardiography (TEE). Thirteen (4.3%) device-related thrombi, 3 (1.0%) ischemic strokes, and 19 (6.3%) non-procedural major bleeding cases were documented, and there were no differences in these complications between groups. The observed rate of all thromboembolic events by Kaplan–Meier analysis decreased by 68.8% (CKD) and 48.6% (non-CKD); moreover, the observed annual rate of bleeding was reduced by 57.5% (CKD) and 11.4% (non-CKD). Our results indicate that LAAC with the WM device is safe and effective in preventing stroke in NVAF patients with and without CKD.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.