Large bowel preparation may cause a substantial change in the gut microbiota and metabolites. Here, we included a bowel prep group and a no-procedure control group and evaluated the effects of bowel prep on the stability of the gut microbiome and metabolome as well as on recovery. Gut microbiota and metabolome compositions were analyzed by 16S rRNA sequencing and capillary electrophoresis time-of-flight mass spectrometry, respectively. Analysis of coefficients at the genus and species level and weighted UniFrac distance showed that, compared with controls, microbiota composition was significantly reduced immediately after the prep but not at 14 days after it. For the gut metabolome profiles, correlation coefficients between before and immediately after the prep were significantly lower than those between before and 14 days after prep and were not significantly different compared with those for between-subject differences. Thirty-two metabolites were significantly changed before and immediately after the prep, but these metabolites recovered within 14 days. In conclusion, bowel preparation has a profound effect on the gut microbiome and metabolome, but the overall composition recovers to baseline within 14 days. To properly conduct studies of the human gut microbiome and metabolome, fecal sampling should be avoided immediately after bowel prep.
Endoscopic ultrasound-guided rendezvous (EUS-RV) is increasingly reported as a treatment option after failed endoscopic retrograde cholangiopancreatography. We developed a novel "hitch-and-ride" catheter for biliary cannulation to reduce the risk of guidewire loss during EUS-RV. We retrospectively evaluated safety and technical success of EUS-RV between June 2011 and May 2016. Biliary cannulation during EUS-RV using three methods - over-the-wire, along-the-wire, and hitch-and-ride - were compared. A total of 30 EUS-RVs were attempted and the technical success rate was 93.3 %, with two failures (one bile duct puncture and one guidewire insertion). After 28 cases of successful guidewire passage, cannulation was attempted by the over-the-wire (n = 13), along-the-wire (n = 4) or hitch-and-ride (n = 11) method. Only the hitch-and-ride method achieved biliary cannulation without guidewire loss or conversion to the other methods. Time to cannulation was shorter with the hitch-and-ride method (4 minutes) than with over-the-wire and along-the-wire methods (9 and 13 minutes, respectively). The adverse event rate of EUS-RV was 23.3 %. A novel hitch-and-ride catheter was feasible for biliary cannulation after EUS-RV.
Background/Aims: Recently, a three-plane symmetric needle with Franseen geometry was developed for endoscopic ultrasound-guided fine needle biopsy (EUS-FNB). In this retrospective study, tissue acquisition per pass was compared between 22-gauge Franseen FNB and standard fine needle aspiration (FNA) needles in patients with solid pancreatic lesions. Methods: Consecutive patients who underwent EUS-FNA or EUS-FNB for solid pancreatic lesions between October 2014 and March 2018 were retrospectively studied. The tissue acquisition rate and the diagnostic performance per session, per pass, and at first pass were compared. Results: A total of 663 passes (300 by the FNB needle and 363 by the standard FNA needle) were performed in 154 patients (71 FNB and 83 FNA). The tissue acquisition rate per session and at first pass in the FNB and FNA groups was 100% and 95% (p=0.13) and 87% and 69% (p=0.007), respectively. The multivariate analysis revealed that among the patients, EUS-FNB (odds ratio, 3.07; p=0.01) was associated with a higher first-pass tissue acquisition rate. While the tissue acquisition rate reached a plateau after the 4th pass with FNA, it reached a plateau after the 2nd pass with FNB. Among the 129 malignant cases, the histological tissue acquisition rate per session was similar (100% and 94%), but the sensitivity by histology alone per session was higher for FNB than for FNA (93% and 73%, p<0.01). Conclusions: The results of our retrospective analysis indicated that compared with a standard FNA needle, a 22-gauge Franseen FNB needle was associated with a higher first-pass tissue acquisition rate.
After reviewing the cases, pneumoperitoneum (57.1%), hepatic needle punctures (42.8%) and direct application of the argon beam to the liver (28.6%) can be considered as risky processes in such events. Caution is necessary in the use of an argon beam in liver surgery to avoid life-threatening gas embolism.
Omicron variants of SARS-CoV-2 acquired escape ability from host immunity and authorized antibody therapeutics and thereby have been spreading worldwide. We reported that patients infected with an early SARS-CoV-2 variant, D614G, and who received subsequent two-dose mRNA vaccination have high neutralizing antibody titer against Omicron lineages.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.