Background— The number of patients with longer follow-up after implantation of an implantable cardioverter-defibrillator is increasing continuously. Defibrillation lead failure is a typical long-term complication. Therefore, the long-term reliability of implantable cardioverter-defibrillator leads has become an increasing concern. The aim of the present study was to assess the annual rate of transvenous defibrillation lead defects related to follow-up time after lead implantation. Methods and Results— A total of 990 consecutive patients who underwent first implantation of an implantable cardioverter-defibrillator between 1992 and May 2005 were analyzed. Median follow-up time was 934 days (interquartile range, 368 to 1870). Overall, 148 defibrillation leads (15%) failed during the follow-up. The estimated lead survival rates at 5 and 8 years after implantation were 85% and 60%, respectively. The annual failure rate increased progressively with time after implantation and reached 20% in 10-year-old leads ( P <0.001). Lead defects affected newer as well as older models. Patients with lead defects were 3 years younger at implantation and more often female. Multiple lead implantation was associated with a trend to a higher rate of defibrillation lead defects ( P =0.06). The major lead complications were insulation defects (56%), lead fractures (12%), loss of ventricular capture (11%), abnormal lead impedance (10%), and sensing failure (10%). Conclusions— An increasing annual lead failure rate is noted primarily during long-term follow-up and reached 20% in 10-year-old leads. Patients with lead defects are younger and more often female.
We investigated the relationship between factor XIII, fibrinogen, blood coagulation screening tests and postoperative bleeding in 98 patients undergoing cardiopulmonary bypass (CPB) surgery. All patients received aprotinin. Blood samples were collected preoperatively (T1),after termination of CPB (T2),12 h (T3) and 24 h (T4) after surgery to determine FXIII activity, fibrinogen, platelet count, prothrombin time (PT), activated partial thromboplastin time (APTT) and D-dimers (DD). Laboratory results were correlated with the chest tube drainage 24 h after surgery and compared between patients with 24-hour chest tube drain volumes in the lower (Group 1) with those in the upper tertile (Group 3). Median FXIII and fibrinogen levels dropped by 33.9% and 34.2%, respectively, during CPB. No association between FXIII activity and the extent of postoperative bleeding was found. However, chest tube bleeding was significantly correlated with preoperative and postoperative fibrinogen. This was confirmed by comparing Groups 1 and 3. Group 3 patients had significantly lower fibrinogen levels than Group 1 at T1 - T4, although most fibrinogen values were within or above the reference range (medians, g/l: 3.5 vs. 4.0, p = 0.043 at T1; 2.3 vs. 2.7, p = 0.015 at T2; 2.9 vs. 3.3, p = 0.008 at T3; 4.2 vs. 5.2, p = 0.002 at T4). There was also a significant relationship of platelet count, PT and APTT, as measured after CPB (T2), with postoperative chest tube drainage. In conclusion, plasma FXIII activity does not influence postoperative bleeding in patients undergoing CPB surgery. There is however an inverse association between preoperative or postoperative plasma fibrinogen levels and postoperative bleeding. These findings indicate a modulation of postoperative bleeding by fibrinogen levels.
Background-The Early Self Controlled Anticoagulation Trial (ESCAT I) showed that anticoagulation self-management after mechanical heart valve replacement decreased complication rates by maintaining INR levels closer to the target range than International Normalized Ratio (INR) home doctor management. The therapeutic range for the INR in that study was between 2.5 and 4.5 for all positions of prosthetic valves. ESCAT II should find out whether lowering the target range for INR self-management would further reduce complication rates. Methods-ESCAT II is a prospective controlled randomized (valves: St. Jude Medical Standard or Medtronic Hall, treatment: conventional/low-dose) multicenter study with 3 300 patients. We present interim results of 1 818 patients. 908 were categorized as having a low-dose target range, which was INR 1.8 to 2.8 for prostheses in aortic position and 2.5 to 3.5 for prostheses in mitral position or in combined valve replacement. The control group (conventional group) with 910 patients aimed at an INR of 2.5 to 4.5 for all valve positions. Results-In the conventional group, 74% of INR values measured were within the therapeutic range. In the low-dose group, 72% of the values were within that range. The linearized thromboembolism rate (% per patient year) was 0.21% for both groups. The bleeding complication rate was 0.56% in the low-dose regimen group versus 0.91% in the conventional group. Conclusions-Early
With the exception of PS and PI, SDP and FFP improved haemostasis and fibrinolysis to a similar degree. The clinical significance of these findings has to be determined in patients with severe acquired PS and PI deficiency requiring plasma transfusions.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.