In this study, an open-cut approach using steel-sheet piles and jet grouting piles for waterproofing was proposed to resolve the problem that ordinary pipe-jacking equipment cannot cross areas with existing anchor cables in soft stratum. The case history of a pipe-jacking project of a sewage treatment plant in the Jinan East Railway Station area was investigated. The mechanical properties of steel-sheet piles, horizontal displacement of piles, and ground surface settlement in the anchor-cable crossing area were investigated based on in situ observations. Numerical investigations were performed using the finite element method (FEM). The effects of existing anchor cables on the mechanical behaviors of retaining structures, deformation variation of the ground, and stability of the excavation were studied. The results indicate that the composite supporting structures of steel-sheet piles and jet grouting piles have a positive effect on waterproofing and deformation control in areas with existing anchor cables. When the steel-sheet pile touched the anchor cable during pile jacking, the compressive stress at the pile cap increased rapidly until it reached 62.8 MPa (the maximum pressure provided by the pile-pressing machine), which is twice the pressure under ordinary conditions. The maximum horizontal displacement of the retaining pile, δv, increased linearly with the excavation depth He. Existing anchor structures behind the excavation can restrain the deformation of the ground and retain the structure to a certain extent. The δv value of the pile with existing anchor structures behind is 6.5 mm or approximately 0.01% of the He value, which is 70% of that of the retaining pile without existing anchor structures. “Groove type” ground surface settlements are found on both sides of the excavation. The maximum ground settlements δh are 0.29% He and 0.05% He, respectively. The plastic zone at both sides of the excavation bottom extends to the ground surface with an angle of about 45°. When an excavation fails, the plastic zone range in the ground with existing anchor cables is significantly larger than it is in the ground without anchor cables. The key contribution of this research is to provide an effective and low-budget treatment for pipe-jacking crossing through an anchor-cable group region. The findings from this study also provide industry practitioners with a comprehensive guide regarding the specific applications and mechanical performance of the crossing excavation for obstacle treatment.
As the composite pile, the precast concrete piles reinforced with cement-treated soil (PCCS) is formed by driving the precast cement (PC) pile into the deep mixing (DM) column, which has been successfully and widely utilized to support buildings and embankments over soft soil. To increase the pile spacing and give full play to the economic merits of the PCCS, a reinforcement scheme, which involves the combined use of rigid piles and flexible columns, employing penetrated PCCSs and floating DM columns is proposed and utilized for soft soil ground treatment. However, there is a lack of feasible method for consolidation behaviors of this combined composite foundation (CCF) reinforced with penetrated PCCSs and floating DM columns under flexible loads. This paper developed an analytical solution to predict the average consolidation degree of this CCF based on a cylinder consolidation model and double-layer ground consolidation theory. The excess pore pressure and average consolidation degree were calculated by considering the composite pile penetration into the cushion. The analytical method agrees well with results obtained by numerical analysis. Additionally, a parametric study was conducted systematically to analyze the effect of key influence factors on the average consolidation degree of this CCF. The results indicate that the consolidation rate of this CCF can be much faster than that of the natural ground. The consolidation rate strongly depends on the compressive modulus and area replacement ratio of PCCSs. The increasing inner core-outer core modulus ratio and the inner core-subsoil modulus ratio increase the consolidation rate of this CCF. In addition, the consolidation rate increases with the gravel cushion-subsoil modulus ratio, while it decreases with the loading period.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.