ObjectCervical pedicle screw (PS) misplacement leads to injury of the spinal cord, nerve root, and vertebral artery. Recently, several investigators reported on the usefulness of a spinal navigation system that improves the accuracy of PS insertion. In this study, the authors assessed the accuracy of cervical pedicle, lateral mass, and odontoid screw insertions placed using a 3D fluoroscopy navigation system, the Iso-C3D unit.MethodsIn this prospective analysis of the authors' initial 50 cases of 3D fluoroscopy–assisted cervical screw insertion, the authors inserted 176 PSs, 58 lateral mass screws, and 5 odontoid screws into the C1–7 vertebrae. They placed screws using intraoperative acquisition of data by the isocentric C-arm fluoroscope and a computer navigation system. They obtained postoperative fine-cut CT scans in all patients and assessed the accuracy of screw insertion.ResultsA PS (≥ 3.5 mm) could be inserted into 24 (63%) of 38 pedicles at the level of C-3, 18 (53%) of 34 pedicles at C-4, 30 (65%) of 46 at C-5, 33 (80%) of 41 at C-6, and 43 (100%) of 43 at C-7. Of 176 PSs inserted into vertebrae between C-2 and C-7, 171 screws (97.2%) were classified as Grade 1 (no pedicle perforation), and 5 screws (2.8%) were classified as Grade 2 (screw perforation of the cortex by up to 2 mm). Clinically significant screw deviation in the present study was considered Grade 3 (screw perforation of the cortex by > 2 mm), and this occurred in 0% of the placements.ConclusionsIn this study, the authors were able to correctly insert cervical PSs using the 3D fluoroscopy and navigation system.
Background: Data of vitamin D sufficiency in Asian patients with osteoporotic fragility hip fractures are limited. This study aimed to obtain data from the Japanese population. Methods: Patients aged 60 years or older with hip fractures were prospectively enrolled. Serum 25-hydroxyvitamin D (25(OH)D) levels were measured. Levels were compared between patients receiving and not receiving treatment for osteoporosis, those with and without previous contralateral hip fractures, and those with femoral neck versus trochanteric fractures. Sex-based differences were also assessed. The serum levels in patients younger than 60 years with extremity fractures were assessed, and differences between elderly and younger patients were evaluated. The individual correlation between 25(OH)D levels and the ultraviolet (UV) index and age was analyzed in elderly patients with hip fractures. Results: The data of 360 patients (aged 84.7 ± 8.2 years), comprising 80 men and 280 women, were analyzed. The mean 25(OH)D level was 16.5 ± 7.2 ng/mL. The prevalence of vitamin D insufficiency (25(OH)D <30 ng/mL) and deficiency (25(OH)D <20 ng/mL) was 93.9% and 71.7%, respectively. A significant difference was noted in the prevalence of vitamin D deficiency between patients with and without previous contralateral hip fractures. Age and 25(OH)D levels were found to be correlated, with no correlation between the UV index and the 25(OH)D levels. The 25(OH)D level in the younger population ( n = 123) was 20.7 ± 8.6 ng/mL, which was significantly higher than that of the elderly. Conclusion: Perennial vitamin D insufficiency is prevalent in elderly Japanese patients with hip fractures.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.