BackgroundOutcomes of catheter ablation of atrial fibrillation (AF) are variable and the predictors of success require further elucidation since the identification of correctable risk factors could help to optimize therapy. We aimed to assess the impact of body mass index (BMI) in the overall safety and efficacy of catheter ablation of AF, with emphasis on the use of cryoballoon ablation and novel oral anticoagulants.Methods and ResultsThere were 2497 consecutive patients undergoing catheter ablation of AF in 7 European high volume centers were stratified according to BMI (normal weight <25 kg/m2, pre‐obese 25–30 kg/m2, obesity 30–35 kg/m2, and morbid obesity ≥35 kg/m2) and comparisons of procedural outcomes evaluated. Pre‐obese and obese patients presented more comorbidities (hypertension, diabetes mellitus, and sleep apnea), and had higher rates of non‐paroxysmal AF ablation procedures. The rate of atrial 12‐month arrhythmia relapse increased alongside with BMI (35.2%, 35.7%, 43.6%, and 48.0% P<0.001). During a median follow‐up of 18.8 months (interquartile range 11–28), after adjusting for all baseline differences, BMI was an independent predictor of relapse (hazard ratio=1.01 per kg/m2; 95% CI 1.01–1.02; P=0.002), adding incremental predictive value to obstructive sleep apnea. BMI was not a predictor for any of the reported complications. Using novel oral anticoagulants and cryoballoon ablation was safe and efficacy was comparable with vitamin‐K antagonists and radiofrequency ablation.ConclusionsObese patients present with a more adverse comorbidity profile, more advanced forms of AF, and have lower chances of being free from AF relapse after ablation. Use of novel oral anticoagulants and cryoballoon ablation may be an option in this patient group.
Aims Atrial fibrillation (AF) is common in hypertrophic cardiomyopathy (HCM). Data on the efficacy of catheter ablation of AF in HCM patients are sparse. Methods and results Observational multicentre study in 137 HCM patients (mean age 55.0 ± 13.4, 29.1% female; 225 ablation procedures). We investigated (i) the efficacy of catheter ablation for AF beyond the initial 12 months; (ii) the available risk scores, stratification schemes and genotype as potential predictors of arrhythmia relapse, and (iii) the impact of cryoballoon vs. radiofrequency in procedural outcomes. Mean follow-up was 43.8 ± 37.0 months. Recurrences after the initial 12-month period post-ablation were frequent, and 24 months after the index procedure, nearly all patients with persistent AF had relapsed, and only 40% of those with paroxysmal AF remained free from arrhythmia recurrence. The APPLE score demonstrated a modest discriminative capacity for AF relapse post-ablation (c-statistic 0.63, 95% CI 0.52–0.75; P = 0.022), while the risk stratification schemes for sudden death did not. On multivariable analysis, left atrium diameter and LV apical aneurysm were independent predictors of recurrence. Fifty-eight patients were genotyped; arrhythmia-free survival was similar among subjects with different gene mutations. Rate of procedural complications was high (9.3%), although reducing over time. Outcome for cryoballoon and radiofrequency ablation was comparable. Conclusion Very late AF relapses post-ablation is common in HCM patients, especially in those with persistent AF. Left atrium size, LV apical aneurysm, and the APPLE score might contribute to identify subjects at higher risk of arrhythmia recurrence. First-time cryoballoon is comparable with radiofrequency ablation.
Introduction: Catheter ablation of atrial fibrillation (AF) has been recently shown to have an impact on the outcome of patients with heart failure and reduced LV ejection fraction (LVEF). We aimed to assess patients with reduced LVEF referred to catheter ablation of AF, and the efficacy and safety of this procedure compared with healthier patients.Methods: 2083 consecutive procedures of catheter ablation of AF in six centers were divided into two groups on the basis of LVEF (≤ vs >35%) and comparisons were performed regarding procedural safety and efficacy.Results: Only 51 (2.4%) of patients had low LVEF. Complication rate was comparable: 8.0% vs 6.9% (P = .760). Low LVEF patients are more frequently in persistent AF at the time of the procedure, have a higher degree of left atrial dilation, and higher CHA 2 DS 2 VASc score. The rate of atrial arrhythmia relapse post-blanking period in the first 12 months was higher in the low LVEF group: 58.0% vs 37.6% (P < .001).During a median follow-up of 14 months (IQR 5-24), after adjusting for all baseline differences, AF duration, paroxysmal AF, CHA 2 DS 2 VASc score, BMI, and indexed LA volume were independent predictors of relapse. LVEF and LVEF ≤ 35% were not identified as predictors of relapse. Conclusions:Patients with reduced LVEF account for only a minority of patients undergoing catheter ablation of AF. However, ablation appears to be as safe as for the general population, and albeit the efficacy seems lower, this appears to be driven by other comorbidities or features, which are more frequent in this population. K E Y W O R D S heart failure, LV ejection fraction, mortality, sinus rhythm, vascular complications SUPPORTING INFORMATION Additional supporting information may be found online in the Supporting Information section. How to cite this article: Providência R, de Asmundis C, Chun J, et al. Catheter ablation of atrial fibrillation in patients with heart failure with reduced ejection fraction: Real world experience from six European centers. J Cardiovasc Electrophysiol.
The S-ICD appears to be as effective and safe as the conventional single chamber TV-ICD. Duration of hospital admission and need of on-demand analgesia are also comparable for S-ICD patients.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.