2001
DOI: 10.1039/b105857f
|View full text |Cite
|
Sign up to set email alerts
|

Untitled

Abstract: Construction, optimization, and testing of a novel single-sided configuration for a semi-permeable [poly(dimethylsiloxane); PDMS] membrane introduction system for mass spectrometry is described. On-line detection of semi-volatile organic compounds of environmental interest is shown, including lindane (a pesticide), hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) (an explosive), butylated hydroxytoluene (BHT) (an antioxidant), 1,2-dichlorobenzene, dimethylmethyl phosphonate (DMMP) (a chemical warfare agent simula… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

2
40
0

Year Published

2001
2001
2013
2013

Publication Types

Select...
9
1

Relationship

1
9

Authors

Journals

citations
Cited by 41 publications
(42 citation statements)
references
References 21 publications
2
40
0
Order By: Relevance
“…Experiments were performed using a modified ThermoFinnigan (San Jose, CA, USA) ITS‐40 ion trap mass spectrometer, described elsewhere 15. The MIMS system, shown in Fig.…”
Section: Methodsmentioning
confidence: 99%
“…Experiments were performed using a modified ThermoFinnigan (San Jose, CA, USA) ITS‐40 ion trap mass spectrometer, described elsewhere 15. The MIMS system, shown in Fig.…”
Section: Methodsmentioning
confidence: 99%
“…Permeated analyte is usually ionized with electron ionization (EI) or chemical ionization (CI), and the parent and fragment ions are then mass analyzed and detected. MIMS has proven to be valuable for the direct online analysis of volatile organic compounds (VOCs) in aqueous [4][5][6][7] and air [4,[8][9][10] samples by demonstrating promising simplicity, speed, and trace-level detection. MIMS has also been used in biological applications [11][12][13] and online environmental monitoring of industrial processes [14].…”
Section: Introductionmentioning
confidence: 99%
“…However, the pressure of 10 À3 Pa inside the SPI source limited the sample input, and the limit of detection (LOD) of benzene was only 25 mg L À1 . Other types of membrane inlet have also been developed to improve the performance of on-line mass spectrometry, [13][14][15][16][17][18][19][20][21][22][23][24] such as the direct external probe hollow ber membrane (HFM), 25 the direct ow-through HFM probe, 13,26 the trap-and-release HFM, 15,21 the intermediate pressure region membrane and the single-side membrane etc.…”
Section: Introductionmentioning
confidence: 99%