2015
DOI: 10.3928/01477447-20150215-57
|View full text |Cite
|
Sign up to set email alerts
|

10-Year Experience With Short Stem Total Hip Arthroplasty

Abstract: Since 1998, short stem total hip arthroplasty (THA) has been performed at the authors' institution. Currently, 30% of THAs are performed with short stems. This article reports on complications that required revision of a short stem THA. Between September 2005 and February 2012, a total of 1953 Metha short stem THAs were performed; of these, 38 required revision due to mechanical complications. In 12 cases, the modular titanium neck adapter failed. In 19 cases, aseptic implant loosening occurred; of these, 11 c… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
41
0
1

Year Published

2016
2016
2020
2020

Publication Types

Select...
5
4

Relationship

1
8

Authors

Journals

citations
Cited by 51 publications
(44 citation statements)
references
References 11 publications
2
41
0
1
Order By: Relevance
“…Lewinski and Floerkemeier [13] described their 10-year experience with short stem TH based on 1953 Metha®short stem procedures with an overall aseptic stem revision rate of 1.3% and 1.9% including 12 modular Ti alloy neck adapter failures based on 190 modular stems with Ti alloy necks implanted before the product recall in November 2006 [16]. Schnurr et al [14] recorded data for 1888 Metha®short stem implantations from 2004 to 2014 with three implanted versions: Modular Ti 6 Al 4 V alloy stems with Ti alloy (n = 314) or CoCr (n = 230) neck adapters and mono-bloc Ti alloy stems (n = 1090) with a mean follow-up of 6 years (range 1-11).…”
Section: )mentioning
confidence: 99%
See 1 more Smart Citation
“…Lewinski and Floerkemeier [13] described their 10-year experience with short stem TH based on 1953 Metha®short stem procedures with an overall aseptic stem revision rate of 1.3% and 1.9% including 12 modular Ti alloy neck adapter failures based on 190 modular stems with Ti alloy necks implanted before the product recall in November 2006 [16]. Schnurr et al [14] recorded data for 1888 Metha®short stem implantations from 2004 to 2014 with three implanted versions: Modular Ti 6 Al 4 V alloy stems with Ti alloy (n = 314) or CoCr (n = 230) neck adapters and mono-bloc Ti alloy stems (n = 1090) with a mean follow-up of 6 years (range 1-11).…”
Section: )mentioning
confidence: 99%
“…The mid-to long-term clinical results for some modular dual taper stem designs are comparable to the implant survivorship of mono-bloc cementless stem designs [7,9,[11][12][13][14][15]. Examining the effectiveness of neck modularity in THA considering sex differences in hip morphology, Traina et al [7] retrospectively reviewed the clinical results of 2131 modular stems implanted in 1051 men and 1080 women.…”
Section: Introductionmentioning
confidence: 99%
“…Subsequently, numerous innovations and modifications of short femoral implants have been introduced to the market [9,15,16]; however, some shortstem designs have already been withdrawn for various reasons [17]. Additionally, only short-and mid-term results are available for most new generation short-stem designs [18,19].…”
Section: Introductionmentioning
confidence: 99%
“…This prosthesis has since been withdrawn from the market. The Metha prosthesis (Aesculap), which was originally similar in design, attempted to offset the disadvantages of the Mayo prosthesis by means of modularity [18]. However, a material failure with a subsequent cone breakage occurred in the region of the adapter in 9.4 % of cases for the titanium cones and in 4.6 % of cases for the cobalt-chromium cones [17].…”
Section: Varus Valgusmentioning
confidence: 99%