Abstract: • CT image quality of aortic root-ascending aorta is challenging. • Non ECG-gated scans are often limited by pulsatility artefacts. • ECG-gated examinations are usually limited by high radiation doses. • Non ECG-gated 128-slice low dose CTAA provides high quality images. • 128-slice CTAA low dose protocol could frequently replace ECG-gated CTAA.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
11
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 19 publications
(11 citation statements)
references
References 24 publications
0
11
0
Order By: Relevance
“…-Mean values and standard deviation of aortoiliac attenuation, noise, and CNR in cohort B are listed in Table 3. No relationship was observed between tube voltage and aortoiliac attenuation (P = .108; slope, 1.45; 95% CI: 20.33, 3.22) (22,23), with an estimated dose per CT angiographic examination of 9.7 and 11.6 mSv. In our study, the full potential of ATVS for radiation dose reduction was not exploited.…”
Section: Discussionmentioning
confidence: 92%
“…-Mean values and standard deviation of aortoiliac attenuation, noise, and CNR in cohort B are listed in Table 3. No relationship was observed between tube voltage and aortoiliac attenuation (P = .108; slope, 1.45; 95% CI: 20.33, 3.22) (22,23), with an estimated dose per CT angiographic examination of 9.7 and 11.6 mSv. In our study, the full potential of ATVS for radiation dose reduction was not exploited.…”
Section: Discussionmentioning
confidence: 92%
“…Sahani et al (17) reported similar image quality for standard CTA and DS-CTA in abdominopelvic vessels; however, they did not explore quantitative metrics. Moreover, Russo et al (18) reported quantitative parameters of 128-slice scanner with high-speed rotation time for imaging thoracoabdominal aorta. In particular, they showed minor motion artifacts and good quality of images also in the abdominal aorta.…”
Section: Discussionmentioning
confidence: 99%
“…Furthermore, the use of fast acquisition would allow reduction of contrast agent, which is again of paramount importance for longterm follow-up. Possibility of reducing volume of contrast agent has been recently reported with promising results (18)(19)(20).…”
Section: Discussionmentioning
confidence: 99%
“…By this time, irreversible damage has occurred during the bronchial development of children’s lungs. This causes a serious negative impact on treatment and prognosis [ 25 ].…”
Section: Discussionmentioning
confidence: 99%