2020
DOI: 10.1016/j.apt.2020.02.022
|View full text |Cite
|
Sign up to set email alerts
|

1T/2H-MoS2 engineered by in-situ ethylene glycol intercalation for improved toluene sensing response at room temperature

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
17
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
6

Relationship

2
4

Authors

Journals

citations
Cited by 32 publications
(17 citation statements)
references
References 65 publications
0
17
0
Order By: Relevance
“…Several reports have demonstrated the formation of 1 T/2H-MoS 2 for various kinds of applications, such as hydrogen evolution reactions [201,203,204], hydrodesulfurization [205], and gas sensor applications [172]. Yang et al [206] demonstrated the formation of the 1 T/2H-mix phase in the molybdenum tungsten sulfate (MWS 2 ) system for acetone gas detections.…”
Section: T-2h Phase Controlmentioning
confidence: 99%
See 3 more Smart Citations
“…Several reports have demonstrated the formation of 1 T/2H-MoS 2 for various kinds of applications, such as hydrogen evolution reactions [201,203,204], hydrodesulfurization [205], and gas sensor applications [172]. Yang et al [206] demonstrated the formation of the 1 T/2H-mix phase in the molybdenum tungsten sulfate (MWS 2 ) system for acetone gas detections.…”
Section: T-2h Phase Controlmentioning
confidence: 99%
“…The enhanced acetone detection performance to several folds was achieved with only 10% of 1 T content in the MWS 2 system. Taufik et al [172] have also successfully demonstrated the formation of 1 T/2H-MoS 2 structure via ethylene glycol (EG) intercalation for improved toluene gas detection performance. The EG intercalation process enhanced the ratio 1 T/2H phase from 1.7 to 4.0 and decreased the conductivity of 1 T/2H-MoS 2 due to EG low conductivity.…”
Section: T-2h Phase Controlmentioning
confidence: 99%
See 2 more Smart Citations
“…However, 1T-MoS 2 is more unstable compared with 2H-MoS 2 for use as a sensor material, suggesting that 1T-MoS 2 cannot be directly used for sensor devices. Recently, it was proposed that the composite between 1T and 2H MoS 2 (1T/2H MoS 2 ) simultaneously possessed a large number of active sites for chemical adsorption and high stability. , However, the change of the resistance under different humidity conditions is still small . Therefore, new strategies for improving the sensing properties of 1T/2H MoS 2 are needed.…”
Section: Introductionmentioning
confidence: 99%