227. Automated Breathing and Metabolic Simulator (ABMS) CO2 Test for Powered and Non-Powered Air-Purifying Respirators, Airline Respirators, and Gas Mask

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0
1

Year Published

2006
2006
2021
2021

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(5 citation statements)
references
References 0 publications
0
4
0
1
Order By: Relevance
“…Similar findings of elevated within-respirator CO 2 levels (i.e., 3.6%) were reported for N95 FFR in a nonhuman study. 53 Prolonged use of an N95 FFR, leading to increased breathing resistance (e.g., due to accumulated water vapor), could potentially increase withinrespirator CO 2 levels, inasmuch as increases of 3-18 mm H 2 O pressure can cause a 3% increase in end-tidal CO 2 levels. 61 Entrainment of air with elevated CO 2 concentrations is an important issue, given that maternal breathing of air mixtures containing 2%-5% CO 2 for 15-30 minutes has been shown to cause increased fetal respiratory rates and vasodilation.…”
Section: Carbon Dioxide Levelsmentioning
confidence: 99%
See 1 more Smart Citation
“…Similar findings of elevated within-respirator CO 2 levels (i.e., 3.6%) were reported for N95 FFR in a nonhuman study. 53 Prolonged use of an N95 FFR, leading to increased breathing resistance (e.g., due to accumulated water vapor), could potentially increase withinrespirator CO 2 levels, inasmuch as increases of 3-18 mm H 2 O pressure can cause a 3% increase in end-tidal CO 2 levels. 61 Entrainment of air with elevated CO 2 concentrations is an important issue, given that maternal breathing of air mixtures containing 2%-5% CO 2 for 15-30 minutes has been shown to cause increased fetal respiratory rates and vasodilation.…”
Section: Carbon Dioxide Levelsmentioning
confidence: 99%
“…10 In a NIOSH nonhuman study using an automated breathing and metabolic simulator that simulates human metabolism, minute ventilation, and human sinusoidal breathing waveforms, similar decreases in within-N95 FFR O 2 levels (i.e., 16.8%) were reported. 53 Patients wearing N95 FFR during dialysis treatment averaged a 9 mm decrease in Pao 2 over baseline values. 54 A recently completed study noted hypoxemia in HCW wearing N95 FFR while performing clinical duties.…”
Section: Oxygen Saturationmentioning
confidence: 99%
“…The respective averages from all 30 NIOSH models of inhaled CO 2 and O 2 were 2.7% and 17.1% without surgical mask and 3.0% and 16.7% with surgical mask. The presence of a surgical mask thus increased the inhaled concentration of CO 2 but did not change peak exhalation or inhalation pressure [ 181 , 190 ]. It should be noted, however, that the different approaches used by NIOSH and the EU to determine respirator average CO 2 concentrations yield different results for the same respirators [ 191 ].…”
Section: Rpd Performance Issues and Challengesmentioning
confidence: 99%
“…Влияние маски на газообмен максимально при наименьшем объёме вдоха, то есть -у людей с небольшой массой тела, а среди медицинских работников много женщин. По данным, упомянутым в [17], у полумасок из непроницаемых материалов концентрация СО 2 ниже, чем у фильтрующих полумасок (до 2,6 и 3,6% соответственно). Но первые мешают общению, что важно для врачей.…”
Section: воздухообменunclassified