238U/230Th disequilibrium measurement for volcanic standard rock samples using a multiple-collector ICPMS.

Abstract: The radioactive disequilibrium measurements between 238 U and 230 Th with a Multi-Collector Inductively Coupled Plasma Mass Spectrometer (MC-ICPMS) were applied to igneous standard rocks distributed by Geological Survey of Japan and Geological Survey of the United States. We modified sample dissolution and Th separation method, as well as Th isotope analysis by MC-ICPMS described by Nakai et al. (2001). High sensitivity of our ICP-MS enabled to analyze less than 10 ng Th. The abundances of U and Th were determ… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
7
0

Year Published

2003
2003
2018
2018

Publication Types

Select...
9

Relationship

4
5

Authors

Journals

citations
Cited by 12 publications
(7 citation statements)
references
References 18 publications
0
7
0
Order By: Relevance
“…The analytical scheme for 238 U-230 Th disequilibrium analysis was described in Fukuda and Nakai (2002). Uranium and thorium were purified using anion exchange resin (AGX1-8; Bio-Rad Laboratories Inc.).…”
Section: Analytical Techniquesmentioning
confidence: 99%
See 1 more Smart Citation
“…The analytical scheme for 238 U-230 Th disequilibrium analysis was described in Fukuda and Nakai (2002). Uranium and thorium were purified using anion exchange resin (AGX1-8; Bio-Rad Laboratories Inc.).…”
Section: Analytical Techniquesmentioning
confidence: 99%
“…An Aridus micro-concentric nebulizer (Cetac Technologies) was used to introduce the sample solutions. The errors for the ( 230 Th/ 232 Th) and ( 238 U/ 232 Th) ratio were estimated respectively as about 0.5% and 2% (Fukuda and Nakai, 2002). About 200-300 mg of different batches of powdered samples were used for ( 234 U/ 238 U) analyses.…”
Section: Analytical Techniquesmentioning
confidence: 99%
“…The mixture was centrifuged and the supernatant was discarded. The precipitate was dissolved in 7 M HNO 3 and Th was separated and purified using AG1-X8 resin (see Fukuda and Nakai (2002), for details). The U/TEVA resin was used for U purification following the method of Yokoyama et al (1999).…”
Section: Methodsmentioning
confidence: 99%
“…The analytical scheme for ( 238 U/ 230 Th) disequilibrium analysis has been described by Fukuda and Nakai (2002). U and Th were purified using anion exchange resin (AGX1-8; Bio-Rad Laboratories Inc.).…”
Section: Analyticalmentioning
confidence: 99%