The 39th International Workshop on Bayesian Inference and Maximum Entropy Methods in Science and Engineering 2019
DOI: 10.3390/proceedings2019033006
|View full text |Cite
|
Sign up to set email alerts
|

2D Deconvolution Using Adaptive Kernel

Abstract: An analysis tool using Adaptive Kernel to solve an ill-posed inverse problem for a 2D model space is introduced. It is applicable for linear and non-linear forward models, for example in tomography and image reconstruction. While an optimisation based on a Gaussian Approximation is possible, it becomes intractable for more than some hundred kernel functions. This is because the determinant of the Hessian of the system has be evaluated. The SVD typically used for 1D problems fails with increasing problem size. … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
1
1

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(2 citation statements)
references
References 15 publications
0
2
0
Order By: Relevance
“…The orange line illustrates the line of sight (LOS) of the infrared (IR)-thermography [30] with focus on the outer divertor target. The IR-thermography measures the tile surface temperature, which is used as input for the implicit version [31] of THEODOR [32]. Applying the Eich-fit [33] allows to determine λ q and the divertor broadening S from the heat flux density profile.…”
Section: An Overview Of Non-calorimetric Diagnostics To Assess the Co...mentioning
confidence: 99%
“…The orange line illustrates the line of sight (LOS) of the infrared (IR)-thermography [30] with focus on the outer divertor target. The IR-thermography measures the tile surface temperature, which is used as input for the implicit version [31] of THEODOR [32]. Applying the Eich-fit [33] allows to determine λ q and the divertor broadening S from the heat flux density profile.…”
Section: An Overview Of Non-calorimetric Diagnostics To Assess the Co...mentioning
confidence: 99%
“…The filaments observed at the outer midplane ultimately reach the divertor target and are measured via the IR camera system installed at AUG [12]. IR cameras measure the divertor surface temperature, and from this, heat fluxes are inferred by using the implicit version [59] of the THEODOR code [12], which solves the heat diffusion equation within the divertor tile.…”
Section: Filament Toroidal Asymmetric Originmentioning
confidence: 99%