2020
DOI: 10.1016/j.jcin.2020.03.015
|View full text |Cite
|
Sign up to set email alerts
|

3-Dimensional Transseptal Puncture Based on Electrographic Characteristics of Fossa Ovalis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

2
18
1

Year Published

2020
2020
2024
2024

Publication Types

Select...
9

Relationship

2
7

Authors

Journals

citations
Cited by 24 publications
(21 citation statements)
references
References 20 publications
2
18
1
Order By: Relevance
“…The amplitude of LA atrial potential was almost over 1 mV except for the fossa ovalis region. The atrial potential characteristic is consistent with electrographic characteristics of the FO which were recently reported by Yu et al 7 They indicated that electrographic characteristics of the FO center are distinct from those of the surrounding regions with atrial electrogram voltage at 0.33 ± 0.21 mV, and the amplitude of atrial potential at the FO annulus was 1.70 ± 0.72 mV. According to the characteristics of the electrical signal and the spatial location of this patient, we identify the AP atrial insertion locates at the anterior edge of left‐side FO, and it is the first report of atrial insertion site at the FO.…”
Section: Discussionsupporting
confidence: 91%
“…The amplitude of LA atrial potential was almost over 1 mV except for the fossa ovalis region. The atrial potential characteristic is consistent with electrographic characteristics of the FO which were recently reported by Yu et al 7 They indicated that electrographic characteristics of the FO center are distinct from those of the surrounding regions with atrial electrogram voltage at 0.33 ± 0.21 mV, and the amplitude of atrial potential at the FO annulus was 1.70 ± 0.72 mV. According to the characteristics of the electrical signal and the spatial location of this patient, we identify the AP atrial insertion locates at the anterior edge of left‐side FO, and it is the first report of atrial insertion site at the FO.…”
Section: Discussionsupporting
confidence: 91%
“…The 3D‐EAM‐guided TSP procedure was pioneered at our institution and has been previously described in detail 3 . Briefly, using a steerable diagnostic catheter (ThermoCool SmartTouch Biosense Webster, Inc.…”
Section: D‐eam‐guided Tspmentioning
confidence: 99%
“…One of the safest features added was the introduction of echocardiography that can be transesophageal or intracardiac. Recently, Yu and colleagues proposed a workflow that included the possibility to see the transseptal needle with 3D EAM, but to visualize the needle, the needle needs to be exposed during the pullback [ 22 ]. We have presented a novel workflow that allows to perform a completely zero-fluoroscopy ablation procedure including the transseptal puncture phase, minimizing the risks of complications (see Video on zero-fluoroscopy transeptal puncture workflow).…”
Section: Discussionmentioning