2018
DOI: 10.1371/journal.pone.0204145
|View full text |Cite
|
Sign up to set email alerts
|

320-row CT transcatheter aortic valve replacement planning with a single reduced contrast media bolus injection

Abstract: ObjectiveTo reduce the iodine load required for CT Transcatheter Aortic Valve Replacement (TAVR) planning on a 320-row scanner by acquiring the two CT TAVR steps (ECG-gated aortic root CTA and non-gated aorto-ilio-femoral CTA) within a single contrast media bolus injection.Methods50 consecutive patients (82.6±6.9 years; 56% female) were prospectively enrolled and underwent a TAVR planning using a 320-row CT, with ECG-gated aortic root CTA immediately followed by a non-gated aorto-iliac acquisition, all within … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
10
2

Year Published

2019
2019
2021
2021

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 15 publications
(14 citation statements)
references
References 29 publications
2
10
2
Order By: Relevance
“…The aortic root CT was acquired in volume mode using a retrospective ECG-gated acquisition and the following CT parameters: 16 cm width, 100 kV, gantry rotation time of 0.275s, auto-mA maxed at 300, acquisition over 1 heartbeat. 16 Acquisition was obtained after a bolus injection of 50-70 mL of iomeprol 400 mg/mL (Iomeron ® , Bracco, Italy), using an automatic power injector at a rate of 3.5 mL/s, followed by a 30-mL saline chaser at a rate of 3 mL/s. The acquisition was triggered using a bolus-tracking technique with the region of interest positioned in the descending thoracic aorta and a 180 Hounsfield units threshold.…”
Section: Computed Tomography Acquisitionmentioning
confidence: 99%
“…The aortic root CT was acquired in volume mode using a retrospective ECG-gated acquisition and the following CT parameters: 16 cm width, 100 kV, gantry rotation time of 0.275s, auto-mA maxed at 300, acquisition over 1 heartbeat. 16 Acquisition was obtained after a bolus injection of 50-70 mL of iomeprol 400 mg/mL (Iomeron ® , Bracco, Italy), using an automatic power injector at a rate of 3.5 mL/s, followed by a 30-mL saline chaser at a rate of 3 mL/s. The acquisition was triggered using a bolus-tracking technique with the region of interest positioned in the descending thoracic aorta and a 180 Hounsfield units threshold.…”
Section: Computed Tomography Acquisitionmentioning
confidence: 99%
“…This separate acquisition approach requires the injection of two separate boluses of the contrast material, resulting in the administration of a considerable amount of iodine. However, most TAVI candidates are elderly patients who frequently have compromised renal function (80)(81)(82). Moreover, accurate measurement of the aortic root annulus maximum size is critical for TAVI planning; thus, image acquisition with retrospective ECG gating to cover the entire cardiac cycle should be considered (78).…”
Section: Transcatheter Aortic Valve Implantation Evaluationmentioning
confidence: 99%
“…Moreover, accurate measurement of the aortic root annulus maximum size is critical for TAVI planning; thus, image acquisition with retrospective ECG gating to cover the entire cardiac cycle should be considered (78). Therefore, the application of the prospective ultra-high-pitch mode with dual-source scanners seems inappropriate for TAVI planning (78,82).…”
Section: Transcatheter Aortic Valve Implantation Evaluationmentioning
confidence: 99%
See 1 more Smart Citation
“…1-7) [1][2][3][4][5][6][7][8]. Recent developments in CT enable simultaneous evaluation of the coronary arteries, aorta, proximal lower extremity arteries CT and MRI of aortic valve stenosis with the use of smaller contrast amount and lower radiation dose than before [9][10][11][12][13][14][15][16][17]. A wide-coverage (256-or 320-slice) detector design or high pitch dual-source CT enables a fast scan covering the aorta, coronary, and proximal femoral arteries ( Fig.…”
Section: Introductionmentioning
confidence: 99%