3D image-based dosimetry for Yttrium-90 radioembolization of hepatocellular carcinoma: Impact of imaging method on absorbed dose estimates

Abstract: Background: To improve therapy outcome of Yttrium-90 selective internal radiation therapy (90 Y SIRT), patientspecific post-therapeutic dosimetry is required. For this purpose, various dosimetric approaches based on different available imaging data have been reported. The aim of this work was to compare post-therapeutic 3D absorbed dose images using Technetium-99m (99m Tc) MAA SPECT/CT, Yttrium-90 (90 Y) bremsstrahlung (BRS) SPECT/CT, and 90 Y PET/CT. Methods: Ten SIRTs of nine patients with unresectable hepat… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
14
0
9

Year Published

2021
2021
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 23 publications
(23 citation statements)
references
References 54 publications
0
14
0
9
Order By: Relevance
“…We evaluated two approaches for target delineation in SIRT. In the first approach, threshold-based contours were automatically delineated on functional images with a fixed 10% threshold chosen to be a reasonable representation of the liver arterial perfusion in SIRT [ 21 , 36 ]. This approach is supposed to inform us if a simplistic threshold-based delineation leads to similar predictive values to a complete “state-of-the-art” clinical workflow.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…We evaluated two approaches for target delineation in SIRT. In the first approach, threshold-based contours were automatically delineated on functional images with a fixed 10% threshold chosen to be a reasonable representation of the liver arterial perfusion in SIRT [ 21 , 36 ]. This approach is supposed to inform us if a simplistic threshold-based delineation leads to similar predictive values to a complete “state-of-the-art” clinical workflow.…”
Section: Discussionmentioning
confidence: 99%
“…Even with a relative calibration method, PET quantification from small activities usually administered with resin microspheres is challenging and should require a dedicated optimization of the PET reconstruction parameters, as exposed above. Controversial results have been reported in the literature depending on the type of image studied and the method used to assess the correlation between pre- and post-treatment dose metrics [ 10 , 15 , 36 , 40 , 41 ]. Apart from the technical gesture that has to be strictly identical, technical discrepancies (different kind of particles, injection flow) between the two procedures should explain the large variation of results reported [ 17 ] and harmonization of both images (SPECT and PET) should increase their similarity in the context of SIRT [ 19 , 42 ].…”
Section: Discussionmentioning
confidence: 99%
“…Son varios los autores que utilizan un factor de calibración relativo calculado a partir de las imágenes clínicas de los propios pacientes [54,[94][95][96]104], asumiendo que la biodistribución de los 99m Tc-MAA es idéntica a la de las 90 Y-microesferas. Mientras que otros estudios proponen el uso de factores de calibración absoluto calculado en base a la sensibilidad del tomógrafo SPECT [60,[105][106][107][108][109][110]. Dicha sensibilidad se determina a partir de imágenes de maniquíes, pero los diseños experimentales también varían de unos trabajos a otros, incluyendo imágenes gammagráficas estáticas de fuentes puntuales en aire [105,106] o de fuentes planas (tipo placa Petri) [109,110]; o imágenes SPECT-CT de maniquís cilíndricos [60,61,105,108].Si la técnica de calibración se basa en imágenes clínicas, es obvio que la segmentación de los VOIs juega de nuevo un papel fundamental, ya que la calibración se puede basar en analizar el tejido hepático completo [54,96,104] o la región abdominal o incluso en el FOV completo del SPECT [111].…”
Section: Problemática De La Dosimetría En La Planificación De Los Tra...unclassified
“…Mientras que otros estudios proponen el uso de factores de calibración absoluto calculado en base a la sensibilidad del tomógrafo SPECT [60,[105][106][107][108][109][110]. Dicha sensibilidad se determina a partir de imágenes de maniquíes, pero los diseños experimentales también varían de unos trabajos a otros, incluyendo imágenes gammagráficas estáticas de fuentes puntuales en aire [105,106] o de fuentes planas (tipo placa Petri) [109,110]; o imágenes SPECT-CT de maniquís cilíndricos [60,61,105,108].Si la técnica de calibración se basa en imágenes clínicas, es obvio que la segmentación de los VOIs juega de nuevo un papel fundamental, ya que la calibración se puede basar en analizar el tejido hepático completo [54,96,104] o la región abdominal o incluso en el FOV completo del SPECT [111]. En este contexto, la EANM publicó una guía en la que se detallan los datos que deben quedar documentados en los informes dosimétricos individualizados de los pacientes [34], en la que se especifica que debe quedar patente si se ha utilizado un factor de calibración absoluto (en base a imágenes experimentales) o relativo a paciente (en base a imágenes clínicas).…”
Section: Problemática De La Dosimetría En La Planificación De Los Tra...unclassified
See 1 more Smart Citation