2021
DOI: 10.1101/2021.07.18.452829
|View full text |Cite
Preprint
|
Sign up to set email alerts
|

3D molecular phenotyping of cleared human brain tissues with light-sheet fluorescence microscopy

Abstract: The combination of optical tissue transparency with immunofluorescence allows the molecular characterization of biological tissues in 3D. However, adult human organs are particularly challenging to become transparent because of the autofluorescence contributions of aged tissues. To meet this challenge, we optimized SHORT (SWITCH - H2O2 - antigen Retrieval - TDE), a procedure based on standard histological treatments in combination with a refined clearing procedure to clear and label portions of the human brain… Show more

Help me understand this report
View published versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
15
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
3
3

Relationship

3
3

Authors

Journals

citations
Cited by 7 publications
(15 citation statements)
references
References 56 publications
(61 reference statements)
0
15
0
Order By: Relevance
“…We also tested the SWITCH and SHIELD protocols that both yielded uniform clearing of the white and gray matter (Figures 1D,E). These clearing protocols optimized for the human brain showed an efficient clearing process in the white and gray matter of the tissue, demonstrating the compatibility of SHIELD protocol with the TDE refractive index matching medium (Costantini et al, 2015;Pesce et al, 2021b). In parallel, we assessed ExM as a clearing protocol variant (Chen et al, 2015;Gao et al, 2017), to investigate 100 µm-thick slices (Figure 1A and Supplementary Figure 1A).…”
Section: Comparison Of Different Clearing Methodsmentioning
confidence: 96%
See 4 more Smart Citations
“…We also tested the SWITCH and SHIELD protocols that both yielded uniform clearing of the white and gray matter (Figures 1D,E). These clearing protocols optimized for the human brain showed an efficient clearing process in the white and gray matter of the tissue, demonstrating the compatibility of SHIELD protocol with the TDE refractive index matching medium (Costantini et al, 2015;Pesce et al, 2021b). In parallel, we assessed ExM as a clearing protocol variant (Chen et al, 2015;Gao et al, 2017), to investigate 100 µm-thick slices (Figure 1A and Supplementary Figure 1A).…”
Section: Comparison Of Different Clearing Methodsmentioning
confidence: 96%
“…The SWITCH protocol was performed following the protocol of Pesce et al (2021b) . The samples were incubated at 4°C for 24 h in 20 ml of SWITCH-Off solution, consisting of 50% PBS titrated to pH 3 using HCl, 25% 0.1 M HCl, 25% 0.1 M potassium hydrogen phthalate (KHP) and 4% glutaraldehyde.…”
Section: Methodsmentioning
confidence: 99%
See 3 more Smart Citations